3 "EventCode": "0x100FE",
4 "EventName": "PM_INST_CMPL",
5 "BriefDescription": "PowerPC instruction completed."
8 "EventCode": "0x1000A",
9 "EventName": "PM_PMC3_REWIND",
10 "BriefDescription": "The speculative event selected for PMC3 rewinds and the counter for PMC3 is not charged."
13 "EventCode": "0x10010",
14 "EventName": "PM_PMC4_OVERFLOW",
15 "BriefDescription": "The event selected for PMC4 caused the event counter to overflow."
18 "EventCode": "0x1001C",
19 "EventName": "PM_ULTRAVISOR_INST_CMPL",
20 "BriefDescription": "PowerPC instruction completed while the thread was in ultravisor state."
23 "EventCode": "0x100F0",
24 "EventName": "PM_CYC",
25 "BriefDescription": "Processor cycles."
28 "EventCode": "0x10020",
29 "EventName": "PM_PMC4_REWIND",
30 "BriefDescription": "The speculative event selected for PMC4 rewinds and the counter for PMC4 is not charged."
33 "EventCode": "0x10022",
34 "EventName": "PM_PMC2_SAVED",
35 "BriefDescription": "The conditions for the speculative event selected for PMC2 are met and PMC2 is charged."
38 "EventCode": "0x10024",
39 "EventName": "PM_PMC5_OVERFLOW",
40 "BriefDescription": "The event selected for PMC5 caused the event counter to overflow."
43 "EventCode": "0x1002A",
44 "EventName": "PM_PMC3_HELD_CYC",
45 "BriefDescription": "Cycles when the speculative counter for PMC3 is frozen."
48 "EventCode": "0x1F15E",
49 "EventName": "PM_MRK_START_PROBE_NOP_CMPL",
50 "BriefDescription": "Marked Start probe nop (AND R0,R0,R0) completed."
53 "EventCode": "0x1006C",
54 "EventName": "PM_RUN_CYC_ST_MODE",
55 "BriefDescription": "Cycles when the run latch is set and the core is in ST mode."
58 "EventCode": "0x101E8",
59 "EventName": "PM_THRESH_EXC_256",
60 "BriefDescription": "Threshold counter exceeded a count of 256."
63 "EventCode": "0x101EC",
64 "EventName": "PM_THRESH_MET",
65 "BriefDescription": "Threshold exceeded."
68 "EventCode": "0x100FA",
69 "EventName": "PM_RUN_LATCH_ANY_THREAD_CYC",
70 "BriefDescription": "Cycles when at least one thread has the run latch set."
73 "EventCode": "0x2000A",
74 "EventName": "PM_HYPERVISOR_CYC",
75 "BriefDescription": "Cycles when the thread is in Hypervisor state. MSR[S HV PR]=010."
78 "EventCode": "0x2000C",
79 "EventName": "PM_RUN_LATCH_ALL_THREADS_CYC",
80 "BriefDescription": "Cycles when the run latch is set for all threads."
83 "EventCode": "0x20010",
84 "EventName": "PM_PMC1_OVERFLOW",
85 "BriefDescription": "The event selected for PMC1 caused the event counter to overflow."
88 "EventCode": "0x2006C",
89 "EventName": "PM_RUN_CYC_SMT4_MODE",
90 "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT4 mode."
93 "EventCode": "0x201E6",
94 "EventName": "PM_THRESH_EXC_32",
95 "BriefDescription": "Threshold counter exceeded a value of 32."
98 "EventCode": "0x201E8",
99 "EventName": "PM_THRESH_EXC_512",
100 "BriefDescription": "Threshold counter exceeded a value of 512."
103 "EventCode": "0x200F4",
104 "EventName": "PM_RUN_CYC",
105 "BriefDescription": "Processor cycles gated by the run latch."
108 "EventCode": "0x30010",
109 "EventName": "PM_PMC2_OVERFLOW",
110 "BriefDescription": "The event selected for PMC2 caused the event counter to overflow."
113 "EventCode": "0x30020",
114 "EventName": "PM_PMC2_REWIND",
115 "BriefDescription": "The speculative event selected for PMC2 rewinds and the counter for PMC2 is not charged."
118 "EventCode": "0x30022",
119 "EventName": "PM_PMC4_SAVED",
120 "BriefDescription": "The conditions for the speculative event selected for PMC4 are met and PMC4 is charged."
123 "EventCode": "0x30024",
124 "EventName": "PM_PMC6_OVERFLOW",
125 "BriefDescription": "The event selected for PMC6 caused the event counter to overflow."
128 "EventCode": "0x3006C",
129 "EventName": "PM_RUN_CYC_SMT2_MODE",
130 "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT2 mode."
133 "EventCode": "0x301E8",
134 "EventName": "PM_THRESH_EXC_64",
135 "BriefDescription": "Threshold counter exceeded a value of 64."
138 "EventCode": "0x301EA",
139 "EventName": "PM_THRESH_EXC_1024",
140 "BriefDescription": "Threshold counter exceeded a value of 1024."
143 "EventCode": "0x40010",
144 "EventName": "PM_PMC3_OVERFLOW",
145 "BriefDescription": "The event selected for PMC3 caused the event counter to overflow."
148 "EventCode": "0x40114",
149 "EventName": "PM_MRK_START_PROBE_NOP_DISP",
150 "BriefDescription": "Marked Start probe nop dispatched. Instruction AND R0,R0,R0."
153 "EventCode": "0x4D010",
154 "EventName": "PM_PMC1_SAVED",
155 "BriefDescription": "The conditions for the speculative event selected for PMC1 are met and PMC1 is charged."
158 "EventCode": "0x4D012",
159 "EventName": "PM_PMC3_SAVED",
160 "BriefDescription": "The conditions for the speculative event selected for PMC3 are met and PMC3 is charged."
163 "EventCode": "0x4D022",
164 "EventName": "PM_HYPERVISOR_INST_CMPL",
165 "BriefDescription": "PowerPC instruction completed while the thread was in hypervisor state."
168 "EventCode": "0x4D026",
169 "EventName": "PM_ULTRAVISOR_CYC",
170 "BriefDescription": "Cycles when the thread is in Ultravisor state. MSR[S HV PR]=110."
173 "EventCode": "0x4D028",
174 "EventName": "PM_PRIVILEGED_CYC",
175 "BriefDescription": "Cycles when the thread is in Privileged state. MSR[S HV PR]=x00."
178 "EventCode": "0x4D02C",
179 "EventName": "PM_PMC1_REWIND",
180 "BriefDescription": "The speculative event selected for PMC1 rewinds and the counter for PMC1 is not charged."
183 "EventCode": "0x40030",
184 "EventName": "PM_INST_FIN",
185 "BriefDescription": "Instruction finished."
188 "EventCode": "0x40134",
189 "EventName": "PM_MRK_INST_TIMEO",
190 "BriefDescription": "Marked instruction finish timeout (instruction was lost)."
193 "EventCode": "0x401EA",
194 "EventName": "PM_THRESH_EXC_128",
195 "BriefDescription": "Threshold counter exceeded a value of 128."
198 "EventCode": "0x500FA",
199 "EventName": "PM_RUN_INST_CMPL",
200 "BriefDescription": "PowerPC instruction completed while the run latch is set."