GNU Linux-libre 6.8.9-gnu
[releases.git] / tools / perf / pmu-events / arch / powerpc / power10 / others.json
1 [
2   {
3     "EventCode": "0x1002C",
4     "EventName": "PM_LD_PREFETCH_CACHE_LINE_MISS",
5     "BriefDescription": "The L1 cache was reloaded with a line that fulfills a prefetch request."
6   },
7   {
8     "EventCode": "0x1505E",
9     "EventName": "PM_LD_HIT_L1",
10     "BriefDescription": "Load finished without experiencing an L1 miss."
11   },
12   {
13     "EventCode": "0x1F056",
14     "EventName": "PM_DISP_SS0_2_INSTR_CYC",
15     "BriefDescription": "Cycles in which Superslice 0 dispatches either 1 or 2 instructions."
16   },
17   {
18     "EventCode": "0x1F05A",
19     "EventName": "PM_DISP_HELD_SYNC_CYC",
20     "BriefDescription": "Cycles dispatch is held because of a synchronizing instruction that requires the ICT to be empty before dispatch."
21   },
22   {
23     "EventCode": "0x10066",
24     "EventName": "PM_ADJUNCT_CYC",
25     "BriefDescription": "Cycles in which the thread is in Adjunct state. MSR[S HV PR] bits = 011."
26   },
27   {
28     "EventCode": "0x100FC",
29     "EventName": "PM_LD_REF_L1",
30     "BriefDescription": "All L1 D cache load references counted at finish, gated by reject. In P9 and earlier this event counted only cacheable loads but in P10 both cacheable and non-cacheable loads are included."
31   },
32   {
33     "EventCode": "0x2E010",
34     "EventName": "PM_ADJUNCT_INST_CMPL",
35     "BriefDescription": "PowerPC instruction completed while the thread was in Adjunct state."
36   },
37   {
38     "EventCode": "0x2E014",
39     "EventName": "PM_STCX_FIN",
40     "BriefDescription": "Conditional store instruction (STCX) finished. LARX and STCX are instructions used to acquire a lock."
41   },
42   {
43     "EventCode": "0x2F054",
44     "EventName": "PM_DISP_SS1_2_INSTR_CYC",
45     "BriefDescription": "Cycles in which Superslice 1 dispatches either 1 or 2 instructions."
46   },
47   {
48     "EventCode": "0x2F056",
49     "EventName": "PM_DISP_SS1_4_INSTR_CYC",
50     "BriefDescription": "Cycles in which Superslice 1 dispatches either 3 or 4 instructions."
51   },
52   {
53     "EventCode": "0x200F2",
54     "EventName": "PM_INST_DISP",
55     "BriefDescription": "PowerPC instruction dispatched."
56   },
57   {
58     "EventCode": "0x200FD",
59     "EventName": "PM_L1_ICACHE_MISS",
60     "BriefDescription": "Demand instruction cache miss."
61   },
62   {
63     "EventCode": "0x3F04A",
64     "EventName": "PM_LSU_ST5_FIN",
65     "BriefDescription": "LSU Finished an internal operation in ST2 port."
66   },
67   {
68     "EventCode": "0x3405A",
69     "EventName": "PM_PRIVILEGED_INST_CMPL",
70     "BriefDescription": "PowerPC instruction completed while the thread was in Privileged state."
71   },
72   {
73     "EventCode": "0x3F054",
74     "EventName": "PM_DISP_SS0_4_INSTR_CYC",
75     "BriefDescription": "Cycles in which Superslice 0 dispatches either 3 or 4 instructions."
76   },
77   {
78     "EventCode": "0x3F056",
79     "EventName": "PM_DISP_SS0_8_INSTR_CYC",
80     "BriefDescription": "Cycles in which Superslice 0 dispatches either 5, 6, 7 or 8 instructions."
81   },
82   {
83     "EventCode": "0x30068",
84     "EventName": "PM_L1_ICACHE_RELOADED_PREF",
85     "BriefDescription": "Counts all instruction cache prefetch reloads (includes demand turned into prefetch)."
86   },
87   {
88     "EventCode": "0x300F6",
89     "EventName": "PM_LD_DEMAND_MISS_L1",
90     "BriefDescription": "The L1 cache was reloaded with a line that fulfills a demand miss request. Counted at reload time, before finish."
91   },
92   {
93     "EventCode": "0x40012",
94     "EventName": "PM_L1_ICACHE_RELOADED_ALL",
95     "BriefDescription": "Counts all instruction cache reloads includes demand, prefetch, prefetch turned into demand and demand turned into prefetch."
96   },
97   {
98     "EventCode": "0x44054",
99     "EventName": "PM_VECTOR_LD_CMPL",
100     "BriefDescription": "Vector load instruction completed."
101   },
102   {
103     "EventCode": "0x4D05E",
104     "EventName": "PM_BR_CMPL",
105     "BriefDescription": "A branch completed. All branches are included."
106   },
107   {
108     "EventCode": "0x400F0",
109     "EventName": "PM_LD_DEMAND_MISS_L1_FIN",
110     "BriefDescription": "Load missed L1, counted at finish time."
111   }
112 ]