arm64: dts: qcom: sm8550: add TRNG node
[linux-modified.git] / kernel / bpf / bpf_inode_storage.c
1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * Copyright (c) 2019 Facebook
4  * Copyright 2020 Google LLC.
5  */
6
7 #include <linux/rculist.h>
8 #include <linux/list.h>
9 #include <linux/hash.h>
10 #include <linux/types.h>
11 #include <linux/spinlock.h>
12 #include <linux/bpf.h>
13 #include <linux/bpf_local_storage.h>
14 #include <net/sock.h>
15 #include <uapi/linux/sock_diag.h>
16 #include <uapi/linux/btf.h>
17 #include <linux/bpf_lsm.h>
18 #include <linux/btf_ids.h>
19 #include <linux/fdtable.h>
20 #include <linux/rcupdate_trace.h>
21
22 DEFINE_BPF_STORAGE_CACHE(inode_cache);
23
24 static struct bpf_local_storage __rcu **
25 inode_storage_ptr(void *owner)
26 {
27         struct inode *inode = owner;
28         struct bpf_storage_blob *bsb;
29
30         bsb = bpf_inode(inode);
31         if (!bsb)
32                 return NULL;
33         return &bsb->storage;
34 }
35
36 static struct bpf_local_storage_data *inode_storage_lookup(struct inode *inode,
37                                                            struct bpf_map *map,
38                                                            bool cacheit_lockit)
39 {
40         struct bpf_local_storage *inode_storage;
41         struct bpf_local_storage_map *smap;
42         struct bpf_storage_blob *bsb;
43
44         bsb = bpf_inode(inode);
45         if (!bsb)
46                 return NULL;
47
48         inode_storage =
49                 rcu_dereference_check(bsb->storage, bpf_rcu_lock_held());
50         if (!inode_storage)
51                 return NULL;
52
53         smap = (struct bpf_local_storage_map *)map;
54         return bpf_local_storage_lookup(inode_storage, smap, cacheit_lockit);
55 }
56
57 void bpf_inode_storage_free(struct inode *inode)
58 {
59         struct bpf_local_storage *local_storage;
60         struct bpf_storage_blob *bsb;
61
62         bsb = bpf_inode(inode);
63         if (!bsb)
64                 return;
65
66         rcu_read_lock();
67
68         local_storage = rcu_dereference(bsb->storage);
69         if (!local_storage) {
70                 rcu_read_unlock();
71                 return;
72         }
73
74         bpf_local_storage_destroy(local_storage);
75         rcu_read_unlock();
76 }
77
78 static void *bpf_fd_inode_storage_lookup_elem(struct bpf_map *map, void *key)
79 {
80         struct bpf_local_storage_data *sdata;
81         struct fd f = fdget_raw(*(int *)key);
82
83         if (!f.file)
84                 return ERR_PTR(-EBADF);
85
86         sdata = inode_storage_lookup(file_inode(f.file), map, true);
87         fdput(f);
88         return sdata ? sdata->data : NULL;
89 }
90
91 static long bpf_fd_inode_storage_update_elem(struct bpf_map *map, void *key,
92                                              void *value, u64 map_flags)
93 {
94         struct bpf_local_storage_data *sdata;
95         struct fd f = fdget_raw(*(int *)key);
96
97         if (!f.file)
98                 return -EBADF;
99         if (!inode_storage_ptr(file_inode(f.file))) {
100                 fdput(f);
101                 return -EBADF;
102         }
103
104         sdata = bpf_local_storage_update(file_inode(f.file),
105                                          (struct bpf_local_storage_map *)map,
106                                          value, map_flags, GFP_ATOMIC);
107         fdput(f);
108         return PTR_ERR_OR_ZERO(sdata);
109 }
110
111 static int inode_storage_delete(struct inode *inode, struct bpf_map *map)
112 {
113         struct bpf_local_storage_data *sdata;
114
115         sdata = inode_storage_lookup(inode, map, false);
116         if (!sdata)
117                 return -ENOENT;
118
119         bpf_selem_unlink(SELEM(sdata), false);
120
121         return 0;
122 }
123
124 static long bpf_fd_inode_storage_delete_elem(struct bpf_map *map, void *key)
125 {
126         struct fd f = fdget_raw(*(int *)key);
127         int err;
128
129         if (!f.file)
130                 return -EBADF;
131
132         err = inode_storage_delete(file_inode(f.file), map);
133         fdput(f);
134         return err;
135 }
136
137 /* *gfp_flags* is a hidden argument provided by the verifier */
138 BPF_CALL_5(bpf_inode_storage_get, struct bpf_map *, map, struct inode *, inode,
139            void *, value, u64, flags, gfp_t, gfp_flags)
140 {
141         struct bpf_local_storage_data *sdata;
142
143         WARN_ON_ONCE(!bpf_rcu_lock_held());
144         if (flags & ~(BPF_LOCAL_STORAGE_GET_F_CREATE))
145                 return (unsigned long)NULL;
146
147         /* explicitly check that the inode_storage_ptr is not
148          * NULL as inode_storage_lookup returns NULL in this case and
149          * bpf_local_storage_update expects the owner to have a
150          * valid storage pointer.
151          */
152         if (!inode || !inode_storage_ptr(inode))
153                 return (unsigned long)NULL;
154
155         sdata = inode_storage_lookup(inode, map, true);
156         if (sdata)
157                 return (unsigned long)sdata->data;
158
159         /* This helper must only called from where the inode is guaranteed
160          * to have a refcount and cannot be freed.
161          */
162         if (flags & BPF_LOCAL_STORAGE_GET_F_CREATE) {
163                 sdata = bpf_local_storage_update(
164                         inode, (struct bpf_local_storage_map *)map, value,
165                         BPF_NOEXIST, gfp_flags);
166                 return IS_ERR(sdata) ? (unsigned long)NULL :
167                                              (unsigned long)sdata->data;
168         }
169
170         return (unsigned long)NULL;
171 }
172
173 BPF_CALL_2(bpf_inode_storage_delete,
174            struct bpf_map *, map, struct inode *, inode)
175 {
176         WARN_ON_ONCE(!bpf_rcu_lock_held());
177         if (!inode)
178                 return -EINVAL;
179
180         /* This helper must only called from where the inode is guaranteed
181          * to have a refcount and cannot be freed.
182          */
183         return inode_storage_delete(inode, map);
184 }
185
186 static int notsupp_get_next_key(struct bpf_map *map, void *key,
187                                 void *next_key)
188 {
189         return -ENOTSUPP;
190 }
191
192 static struct bpf_map *inode_storage_map_alloc(union bpf_attr *attr)
193 {
194         return bpf_local_storage_map_alloc(attr, &inode_cache, false);
195 }
196
197 static void inode_storage_map_free(struct bpf_map *map)
198 {
199         bpf_local_storage_map_free(map, &inode_cache, NULL);
200 }
201
202 const struct bpf_map_ops inode_storage_map_ops = {
203         .map_meta_equal = bpf_map_meta_equal,
204         .map_alloc_check = bpf_local_storage_map_alloc_check,
205         .map_alloc = inode_storage_map_alloc,
206         .map_free = inode_storage_map_free,
207         .map_get_next_key = notsupp_get_next_key,
208         .map_lookup_elem = bpf_fd_inode_storage_lookup_elem,
209         .map_update_elem = bpf_fd_inode_storage_update_elem,
210         .map_delete_elem = bpf_fd_inode_storage_delete_elem,
211         .map_check_btf = bpf_local_storage_map_check_btf,
212         .map_mem_usage = bpf_local_storage_map_mem_usage,
213         .map_btf_id = &bpf_local_storage_map_btf_id[0],
214         .map_owner_storage_ptr = inode_storage_ptr,
215 };
216
217 BTF_ID_LIST_SINGLE(bpf_inode_storage_btf_ids, struct, inode)
218
219 const struct bpf_func_proto bpf_inode_storage_get_proto = {
220         .func           = bpf_inode_storage_get,
221         .gpl_only       = false,
222         .ret_type       = RET_PTR_TO_MAP_VALUE_OR_NULL,
223         .arg1_type      = ARG_CONST_MAP_PTR,
224         .arg2_type      = ARG_PTR_TO_BTF_ID_OR_NULL,
225         .arg2_btf_id    = &bpf_inode_storage_btf_ids[0],
226         .arg3_type      = ARG_PTR_TO_MAP_VALUE_OR_NULL,
227         .arg4_type      = ARG_ANYTHING,
228 };
229
230 const struct bpf_func_proto bpf_inode_storage_delete_proto = {
231         .func           = bpf_inode_storage_delete,
232         .gpl_only       = false,
233         .ret_type       = RET_INTEGER,
234         .arg1_type      = ARG_CONST_MAP_PTR,
235         .arg2_type      = ARG_PTR_TO_BTF_ID_OR_NULL,
236         .arg2_btf_id    = &bpf_inode_storage_btf_ids[0],
237 };