arm64: dts: qcom: sm8550: add TRNG node
[linux-modified.git] / drivers / power / supply / axp20x_battery.c
1 /*
2  * Battery power supply driver for X-Powers AXP20X and AXP22X PMICs
3  *
4  * Copyright 2016 Free Electrons NextThing Co.
5  *      Quentin Schulz <quentin.schulz@free-electrons.com>
6  *
7  * This driver is based on a previous upstreaming attempt by:
8  *      Bruno PrĂ©mont <bonbons@linux-vserver.org>
9  *
10  * This file is subject to the terms and conditions of the GNU General
11  * Public License. See the file "COPYING" in the main directory of this
12  * archive for more details.
13  *
14  * This program is distributed in the hope that it will be useful,
15  * but WITHOUT ANY WARRANTY; without even the implied warranty of
16  * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
17  * GNU General Public License for more details.
18  */
19
20 #include <linux/err.h>
21 #include <linux/interrupt.h>
22 #include <linux/irq.h>
23 #include <linux/module.h>
24 #include <linux/of.h>
25 #include <linux/platform_device.h>
26 #include <linux/power_supply.h>
27 #include <linux/regmap.h>
28 #include <linux/slab.h>
29 #include <linux/time.h>
30 #include <linux/iio/iio.h>
31 #include <linux/iio/consumer.h>
32 #include <linux/mfd/axp20x.h>
33
34 #define AXP20X_PWR_STATUS_BAT_CHARGING  BIT(2)
35
36 #define AXP20X_PWR_OP_BATT_PRESENT      BIT(5)
37 #define AXP20X_PWR_OP_BATT_ACTIVATED    BIT(3)
38
39 #define AXP209_FG_PERCENT               GENMASK(6, 0)
40 #define AXP22X_FG_VALID                 BIT(7)
41
42 #define AXP20X_CHRG_CTRL1_ENABLE        BIT(7)
43 #define AXP20X_CHRG_CTRL1_TGT_VOLT      GENMASK(6, 5)
44 #define AXP20X_CHRG_CTRL1_TGT_4_1V      (0 << 5)
45 #define AXP20X_CHRG_CTRL1_TGT_4_15V     (1 << 5)
46 #define AXP20X_CHRG_CTRL1_TGT_4_2V      (2 << 5)
47 #define AXP20X_CHRG_CTRL1_TGT_4_36V     (3 << 5)
48
49 #define AXP22X_CHRG_CTRL1_TGT_4_22V     (1 << 5)
50 #define AXP22X_CHRG_CTRL1_TGT_4_24V     (3 << 5)
51
52 #define AXP813_CHRG_CTRL1_TGT_4_35V     (3 << 5)
53
54 #define AXP20X_CHRG_CTRL1_TGT_CURR      GENMASK(3, 0)
55
56 #define AXP20X_V_OFF_MASK               GENMASK(2, 0)
57
58 struct axp20x_batt_ps;
59
60 struct axp_data {
61         int     ccc_scale;
62         int     ccc_offset;
63         bool    has_fg_valid;
64         int     (*get_max_voltage)(struct axp20x_batt_ps *batt, int *val);
65         int     (*set_max_voltage)(struct axp20x_batt_ps *batt, int val);
66 };
67
68 struct axp20x_batt_ps {
69         struct regmap *regmap;
70         struct power_supply *batt;
71         struct device *dev;
72         struct iio_channel *batt_chrg_i;
73         struct iio_channel *batt_dischrg_i;
74         struct iio_channel *batt_v;
75         /* Maximum constant charge current */
76         unsigned int max_ccc;
77         const struct axp_data   *data;
78 };
79
80 static int axp20x_battery_get_max_voltage(struct axp20x_batt_ps *axp20x_batt,
81                                           int *val)
82 {
83         int ret, reg;
84
85         ret = regmap_read(axp20x_batt->regmap, AXP20X_CHRG_CTRL1, &reg);
86         if (ret)
87                 return ret;
88
89         switch (reg & AXP20X_CHRG_CTRL1_TGT_VOLT) {
90         case AXP20X_CHRG_CTRL1_TGT_4_1V:
91                 *val = 4100000;
92                 break;
93         case AXP20X_CHRG_CTRL1_TGT_4_15V:
94                 *val = 4150000;
95                 break;
96         case AXP20X_CHRG_CTRL1_TGT_4_2V:
97                 *val = 4200000;
98                 break;
99         case AXP20X_CHRG_CTRL1_TGT_4_36V:
100                 *val = 4360000;
101                 break;
102         default:
103                 return -EINVAL;
104         }
105
106         return 0;
107 }
108
109 static int axp22x_battery_get_max_voltage(struct axp20x_batt_ps *axp20x_batt,
110                                           int *val)
111 {
112         int ret, reg;
113
114         ret = regmap_read(axp20x_batt->regmap, AXP20X_CHRG_CTRL1, &reg);
115         if (ret)
116                 return ret;
117
118         switch (reg & AXP20X_CHRG_CTRL1_TGT_VOLT) {
119         case AXP20X_CHRG_CTRL1_TGT_4_1V:
120                 *val = 4100000;
121                 break;
122         case AXP20X_CHRG_CTRL1_TGT_4_2V:
123                 *val = 4200000;
124                 break;
125         case AXP22X_CHRG_CTRL1_TGT_4_22V:
126                 *val = 4220000;
127                 break;
128         case AXP22X_CHRG_CTRL1_TGT_4_24V:
129                 *val = 4240000;
130                 break;
131         default:
132                 return -EINVAL;
133         }
134
135         return 0;
136 }
137
138 static int axp813_battery_get_max_voltage(struct axp20x_batt_ps *axp20x_batt,
139                                           int *val)
140 {
141         int ret, reg;
142
143         ret = regmap_read(axp20x_batt->regmap, AXP20X_CHRG_CTRL1, &reg);
144         if (ret)
145                 return ret;
146
147         switch (reg & AXP20X_CHRG_CTRL1_TGT_VOLT) {
148         case AXP20X_CHRG_CTRL1_TGT_4_1V:
149                 *val = 4100000;
150                 break;
151         case AXP20X_CHRG_CTRL1_TGT_4_15V:
152                 *val = 4150000;
153                 break;
154         case AXP20X_CHRG_CTRL1_TGT_4_2V:
155                 *val = 4200000;
156                 break;
157         case AXP813_CHRG_CTRL1_TGT_4_35V:
158                 *val = 4350000;
159                 break;
160         default:
161                 return -EINVAL;
162         }
163
164         return 0;
165 }
166
167 static int axp20x_get_constant_charge_current(struct axp20x_batt_ps *axp,
168                                               int *val)
169 {
170         int ret;
171
172         ret = regmap_read(axp->regmap, AXP20X_CHRG_CTRL1, val);
173         if (ret)
174                 return ret;
175
176         *val &= AXP20X_CHRG_CTRL1_TGT_CURR;
177
178         *val = *val * axp->data->ccc_scale + axp->data->ccc_offset;
179
180         return 0;
181 }
182
183 static int axp20x_battery_get_prop(struct power_supply *psy,
184                                    enum power_supply_property psp,
185                                    union power_supply_propval *val)
186 {
187         struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
188         int ret = 0, reg, val1;
189
190         switch (psp) {
191         case POWER_SUPPLY_PROP_PRESENT:
192         case POWER_SUPPLY_PROP_ONLINE:
193                 ret = regmap_read(axp20x_batt->regmap, AXP20X_PWR_OP_MODE,
194                                   &reg);
195                 if (ret)
196                         return ret;
197
198                 val->intval = !!(reg & AXP20X_PWR_OP_BATT_PRESENT);
199                 break;
200
201         case POWER_SUPPLY_PROP_STATUS:
202                 ret = regmap_read(axp20x_batt->regmap, AXP20X_PWR_INPUT_STATUS,
203                                   &reg);
204                 if (ret)
205                         return ret;
206
207                 if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
208                         val->intval = POWER_SUPPLY_STATUS_CHARGING;
209                         return 0;
210                 }
211
212                 ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i,
213                                                  &val1);
214                 if (ret)
215                         return ret;
216
217                 if (val1) {
218                         val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
219                         return 0;
220                 }
221
222                 ret = regmap_read(axp20x_batt->regmap, AXP20X_FG_RES, &val1);
223                 if (ret)
224                         return ret;
225
226                 /*
227                  * Fuel Gauge data takes 7 bits but the stored value seems to be
228                  * directly the raw percentage without any scaling to 7 bits.
229                  */
230                 if ((val1 & AXP209_FG_PERCENT) == 100)
231                         val->intval = POWER_SUPPLY_STATUS_FULL;
232                 else
233                         val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
234                 break;
235
236         case POWER_SUPPLY_PROP_HEALTH:
237                 ret = regmap_read(axp20x_batt->regmap, AXP20X_PWR_OP_MODE,
238                                   &val1);
239                 if (ret)
240                         return ret;
241
242                 if (val1 & AXP20X_PWR_OP_BATT_ACTIVATED) {
243                         val->intval = POWER_SUPPLY_HEALTH_DEAD;
244                         return 0;
245                 }
246
247                 val->intval = POWER_SUPPLY_HEALTH_GOOD;
248                 break;
249
250         case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
251                 ret = axp20x_get_constant_charge_current(axp20x_batt,
252                                                          &val->intval);
253                 if (ret)
254                         return ret;
255                 break;
256
257         case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
258                 val->intval = axp20x_batt->max_ccc;
259                 break;
260
261         case POWER_SUPPLY_PROP_CURRENT_NOW:
262                 ret = regmap_read(axp20x_batt->regmap, AXP20X_PWR_INPUT_STATUS,
263                                   &reg);
264                 if (ret)
265                         return ret;
266
267                 if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
268                         ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval);
269                 } else {
270                         ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1);
271                         val->intval = -val1;
272                 }
273                 if (ret)
274                         return ret;
275
276                 /* IIO framework gives mA but Power Supply framework gives uA */
277                 val->intval *= 1000;
278                 break;
279
280         case POWER_SUPPLY_PROP_CAPACITY:
281                 /* When no battery is present, return capacity is 100% */
282                 ret = regmap_read(axp20x_batt->regmap, AXP20X_PWR_OP_MODE,
283                                   &reg);
284                 if (ret)
285                         return ret;
286
287                 if (!(reg & AXP20X_PWR_OP_BATT_PRESENT)) {
288                         val->intval = 100;
289                         return 0;
290                 }
291
292                 ret = regmap_read(axp20x_batt->regmap, AXP20X_FG_RES, &reg);
293                 if (ret)
294                         return ret;
295
296                 if (axp20x_batt->data->has_fg_valid && !(reg & AXP22X_FG_VALID))
297                         return -EINVAL;
298
299                 /*
300                  * Fuel Gauge data takes 7 bits but the stored value seems to be
301                  * directly the raw percentage without any scaling to 7 bits.
302                  */
303                 val->intval = reg & AXP209_FG_PERCENT;
304                 break;
305
306         case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
307                 return axp20x_batt->data->get_max_voltage(axp20x_batt,
308                                                           &val->intval);
309
310         case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
311                 ret = regmap_read(axp20x_batt->regmap, AXP20X_V_OFF, &reg);
312                 if (ret)
313                         return ret;
314
315                 val->intval = 2600000 + 100000 * (reg & AXP20X_V_OFF_MASK);
316                 break;
317
318         case POWER_SUPPLY_PROP_VOLTAGE_NOW:
319                 ret = iio_read_channel_processed(axp20x_batt->batt_v,
320                                                  &val->intval);
321                 if (ret)
322                         return ret;
323
324                 /* IIO framework gives mV but Power Supply framework gives uV */
325                 val->intval *= 1000;
326                 break;
327
328         default:
329                 return -EINVAL;
330         }
331
332         return 0;
333 }
334
335 static int axp22x_battery_set_max_voltage(struct axp20x_batt_ps *axp20x_batt,
336                                           int val)
337 {
338         switch (val) {
339         case 4100000:
340                 val = AXP20X_CHRG_CTRL1_TGT_4_1V;
341                 break;
342
343         case 4200000:
344                 val = AXP20X_CHRG_CTRL1_TGT_4_2V;
345                 break;
346
347         default:
348                 /*
349                  * AXP20x max voltage can be set to 4.36V and AXP22X max voltage
350                  * can be set to 4.22V and 4.24V, but these voltages are too
351                  * high for Lithium based batteries (AXP PMICs are supposed to
352                  * be used with these kinds of battery).
353                  */
354                 return -EINVAL;
355         }
356
357         return regmap_update_bits(axp20x_batt->regmap, AXP20X_CHRG_CTRL1,
358                                   AXP20X_CHRG_CTRL1_TGT_VOLT, val);
359 }
360
361 static int axp20x_battery_set_max_voltage(struct axp20x_batt_ps *axp20x_batt,
362                                           int val)
363 {
364         switch (val) {
365         case 4100000:
366                 val = AXP20X_CHRG_CTRL1_TGT_4_1V;
367                 break;
368
369         case 4150000:
370                 val = AXP20X_CHRG_CTRL1_TGT_4_15V;
371                 break;
372
373         case 4200000:
374                 val = AXP20X_CHRG_CTRL1_TGT_4_2V;
375                 break;
376
377         default:
378                 /*
379                  * AXP20x max voltage can be set to 4.36V and AXP22X max voltage
380                  * can be set to 4.22V and 4.24V, but these voltages are too
381                  * high for Lithium based batteries (AXP PMICs are supposed to
382                  * be used with these kinds of battery).
383                  */
384                 return -EINVAL;
385         }
386
387         return regmap_update_bits(axp20x_batt->regmap, AXP20X_CHRG_CTRL1,
388                                   AXP20X_CHRG_CTRL1_TGT_VOLT, val);
389 }
390
391 static int axp20x_set_constant_charge_current(struct axp20x_batt_ps *axp_batt,
392                                               int charge_current)
393 {
394         if (charge_current > axp_batt->max_ccc)
395                 return -EINVAL;
396
397         charge_current = (charge_current - axp_batt->data->ccc_offset) /
398                 axp_batt->data->ccc_scale;
399
400         if (charge_current > AXP20X_CHRG_CTRL1_TGT_CURR || charge_current < 0)
401                 return -EINVAL;
402
403         return regmap_update_bits(axp_batt->regmap, AXP20X_CHRG_CTRL1,
404                                   AXP20X_CHRG_CTRL1_TGT_CURR, charge_current);
405 }
406
407 static int axp20x_set_max_constant_charge_current(struct axp20x_batt_ps *axp,
408                                                   int charge_current)
409 {
410         bool lower_max = false;
411
412         charge_current = (charge_current - axp->data->ccc_offset) /
413                 axp->data->ccc_scale;
414
415         if (charge_current > AXP20X_CHRG_CTRL1_TGT_CURR || charge_current < 0)
416                 return -EINVAL;
417
418         charge_current = charge_current * axp->data->ccc_scale +
419                 axp->data->ccc_offset;
420
421         if (charge_current > axp->max_ccc)
422                 dev_warn(axp->dev,
423                          "Setting max constant charge current higher than previously defined. Note that increasing the constant charge current may damage your battery.\n");
424         else
425                 lower_max = true;
426
427         axp->max_ccc = charge_current;
428
429         if (lower_max) {
430                 int current_cc;
431
432                 axp20x_get_constant_charge_current(axp, &current_cc);
433                 if (current_cc > charge_current)
434                         axp20x_set_constant_charge_current(axp, charge_current);
435         }
436
437         return 0;
438 }
439 static int axp20x_set_voltage_min_design(struct axp20x_batt_ps *axp_batt,
440                                          int min_voltage)
441 {
442         int val1 = (min_voltage - 2600000) / 100000;
443
444         if (val1 < 0 || val1 > AXP20X_V_OFF_MASK)
445                 return -EINVAL;
446
447         return regmap_update_bits(axp_batt->regmap, AXP20X_V_OFF,
448                                   AXP20X_V_OFF_MASK, val1);
449 }
450
451 static int axp20x_battery_set_prop(struct power_supply *psy,
452                                    enum power_supply_property psp,
453                                    const union power_supply_propval *val)
454 {
455         struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
456
457         switch (psp) {
458         case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
459                 return axp20x_set_voltage_min_design(axp20x_batt, val->intval);
460
461         case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
462                 return axp20x_batt->data->set_max_voltage(axp20x_batt, val->intval);
463
464         case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
465                 return axp20x_set_constant_charge_current(axp20x_batt,
466                                                           val->intval);
467         case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
468                 return axp20x_set_max_constant_charge_current(axp20x_batt,
469                                                               val->intval);
470         case POWER_SUPPLY_PROP_STATUS:
471                 switch (val->intval) {
472                 case POWER_SUPPLY_STATUS_CHARGING:
473                         return regmap_update_bits(axp20x_batt->regmap, AXP20X_CHRG_CTRL1,
474                                 AXP20X_CHRG_CTRL1_ENABLE, AXP20X_CHRG_CTRL1_ENABLE);
475
476                 case POWER_SUPPLY_STATUS_DISCHARGING:
477                 case POWER_SUPPLY_STATUS_NOT_CHARGING:
478                         return regmap_update_bits(axp20x_batt->regmap, AXP20X_CHRG_CTRL1,
479                                 AXP20X_CHRG_CTRL1_ENABLE, 0);
480                 }
481                 fallthrough;
482         default:
483                 return -EINVAL;
484         }
485 }
486
487 static enum power_supply_property axp20x_battery_props[] = {
488         POWER_SUPPLY_PROP_PRESENT,
489         POWER_SUPPLY_PROP_ONLINE,
490         POWER_SUPPLY_PROP_STATUS,
491         POWER_SUPPLY_PROP_VOLTAGE_NOW,
492         POWER_SUPPLY_PROP_CURRENT_NOW,
493         POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
494         POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX,
495         POWER_SUPPLY_PROP_HEALTH,
496         POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
497         POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
498         POWER_SUPPLY_PROP_CAPACITY,
499 };
500
501 static int axp20x_battery_prop_writeable(struct power_supply *psy,
502                                          enum power_supply_property psp)
503 {
504         return psp == POWER_SUPPLY_PROP_STATUS ||
505                psp == POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN ||
506                psp == POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN ||
507                psp == POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT ||
508                psp == POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX;
509 }
510
511 static const struct power_supply_desc axp20x_batt_ps_desc = {
512         .name = "axp20x-battery",
513         .type = POWER_SUPPLY_TYPE_BATTERY,
514         .properties = axp20x_battery_props,
515         .num_properties = ARRAY_SIZE(axp20x_battery_props),
516         .property_is_writeable = axp20x_battery_prop_writeable,
517         .get_property = axp20x_battery_get_prop,
518         .set_property = axp20x_battery_set_prop,
519 };
520
521 static const struct axp_data axp209_data = {
522         .ccc_scale = 100000,
523         .ccc_offset = 300000,
524         .get_max_voltage = axp20x_battery_get_max_voltage,
525         .set_max_voltage = axp20x_battery_set_max_voltage,
526 };
527
528 static const struct axp_data axp221_data = {
529         .ccc_scale = 150000,
530         .ccc_offset = 300000,
531         .has_fg_valid = true,
532         .get_max_voltage = axp22x_battery_get_max_voltage,
533         .set_max_voltage = axp22x_battery_set_max_voltage,
534 };
535
536 static const struct axp_data axp813_data = {
537         .ccc_scale = 200000,
538         .ccc_offset = 200000,
539         .has_fg_valid = true,
540         .get_max_voltage = axp813_battery_get_max_voltage,
541         .set_max_voltage = axp20x_battery_set_max_voltage,
542 };
543
544 static const struct of_device_id axp20x_battery_ps_id[] = {
545         {
546                 .compatible = "x-powers,axp209-battery-power-supply",
547                 .data = (void *)&axp209_data,
548         }, {
549                 .compatible = "x-powers,axp221-battery-power-supply",
550                 .data = (void *)&axp221_data,
551         }, {
552                 .compatible = "x-powers,axp813-battery-power-supply",
553                 .data = (void *)&axp813_data,
554         }, { /* sentinel */ },
555 };
556 MODULE_DEVICE_TABLE(of, axp20x_battery_ps_id);
557
558 static int axp20x_power_probe(struct platform_device *pdev)
559 {
560         struct axp20x_batt_ps *axp20x_batt;
561         struct power_supply_config psy_cfg = {};
562         struct power_supply_battery_info *info;
563         struct device *dev = &pdev->dev;
564
565         if (!of_device_is_available(pdev->dev.of_node))
566                 return -ENODEV;
567
568         axp20x_batt = devm_kzalloc(&pdev->dev, sizeof(*axp20x_batt),
569                                    GFP_KERNEL);
570         if (!axp20x_batt)
571                 return -ENOMEM;
572
573         axp20x_batt->dev = &pdev->dev;
574
575         axp20x_batt->batt_v = devm_iio_channel_get(&pdev->dev, "batt_v");
576         if (IS_ERR(axp20x_batt->batt_v)) {
577                 if (PTR_ERR(axp20x_batt->batt_v) == -ENODEV)
578                         return -EPROBE_DEFER;
579                 return PTR_ERR(axp20x_batt->batt_v);
580         }
581
582         axp20x_batt->batt_chrg_i = devm_iio_channel_get(&pdev->dev,
583                                                         "batt_chrg_i");
584         if (IS_ERR(axp20x_batt->batt_chrg_i)) {
585                 if (PTR_ERR(axp20x_batt->batt_chrg_i) == -ENODEV)
586                         return -EPROBE_DEFER;
587                 return PTR_ERR(axp20x_batt->batt_chrg_i);
588         }
589
590         axp20x_batt->batt_dischrg_i = devm_iio_channel_get(&pdev->dev,
591                                                            "batt_dischrg_i");
592         if (IS_ERR(axp20x_batt->batt_dischrg_i)) {
593                 if (PTR_ERR(axp20x_batt->batt_dischrg_i) == -ENODEV)
594                         return -EPROBE_DEFER;
595                 return PTR_ERR(axp20x_batt->batt_dischrg_i);
596         }
597
598         axp20x_batt->regmap = dev_get_regmap(pdev->dev.parent, NULL);
599         platform_set_drvdata(pdev, axp20x_batt);
600
601         psy_cfg.drv_data = axp20x_batt;
602         psy_cfg.of_node = pdev->dev.of_node;
603
604         axp20x_batt->data = (struct axp_data *)of_device_get_match_data(dev);
605
606         axp20x_batt->batt = devm_power_supply_register(&pdev->dev,
607                                                        &axp20x_batt_ps_desc,
608                                                        &psy_cfg);
609         if (IS_ERR(axp20x_batt->batt)) {
610                 dev_err(&pdev->dev, "failed to register power supply: %ld\n",
611                         PTR_ERR(axp20x_batt->batt));
612                 return PTR_ERR(axp20x_batt->batt);
613         }
614
615         if (!power_supply_get_battery_info(axp20x_batt->batt, &info)) {
616                 int vmin = info->voltage_min_design_uv;
617                 int ccc = info->constant_charge_current_max_ua;
618
619                 if (vmin > 0 && axp20x_set_voltage_min_design(axp20x_batt,
620                                                               vmin))
621                         dev_err(&pdev->dev,
622                                 "couldn't set voltage_min_design\n");
623
624                 /* Set max to unverified value to be able to set CCC */
625                 axp20x_batt->max_ccc = ccc;
626
627                 if (ccc <= 0 || axp20x_set_constant_charge_current(axp20x_batt,
628                                                                    ccc)) {
629                         dev_err(&pdev->dev,
630                                 "couldn't set constant charge current from DT: fallback to minimum value\n");
631                         ccc = 300000;
632                         axp20x_batt->max_ccc = ccc;
633                         axp20x_set_constant_charge_current(axp20x_batt, ccc);
634                 }
635         }
636
637         /*
638          * Update max CCC to a valid value if battery info is present or set it
639          * to current register value by default.
640          */
641         axp20x_get_constant_charge_current(axp20x_batt,
642                                            &axp20x_batt->max_ccc);
643
644         return 0;
645 }
646
647 static struct platform_driver axp20x_batt_driver = {
648         .probe    = axp20x_power_probe,
649         .driver   = {
650                 .name  = "axp20x-battery-power-supply",
651                 .of_match_table = axp20x_battery_ps_id,
652         },
653 };
654
655 module_platform_driver(axp20x_batt_driver);
656
657 MODULE_DESCRIPTION("Battery power supply driver for AXP20X and AXP22X PMICs");
658 MODULE_AUTHOR("Quentin Schulz <quentin.schulz@free-electrons.com>");
659 MODULE_LICENSE("GPL");