GNU Linux-libre 4.19.268-gnu1
[releases.git] / drivers / pci / hotplug / rpadlpar_core.c
1 // SPDX-License-Identifier: GPL-2.0+
2 /*
3  * Interface for Dynamic Logical Partitioning of I/O Slots on
4  * RPA-compliant PPC64 platform.
5  *
6  * John Rose <johnrose@austin.ibm.com>
7  * Linda Xie <lxie@us.ibm.com>
8  *
9  * October 2003
10  *
11  * Copyright (C) 2003 IBM.
12  */
13
14 #undef DEBUG
15
16 #include <linux/init.h>
17 #include <linux/module.h>
18 #include <linux/pci.h>
19 #include <linux/string.h>
20 #include <linux/vmalloc.h>
21
22 #include <asm/pci-bridge.h>
23 #include <linux/mutex.h>
24 #include <asm/rtas.h>
25 #include <asm/vio.h>
26 #include <linux/firmware.h>
27
28 #include "../pci.h"
29 #include "rpaphp.h"
30 #include "rpadlpar.h"
31
32 static DEFINE_MUTEX(rpadlpar_mutex);
33
34 #define DLPAR_MODULE_NAME "rpadlpar_io"
35
36 #define NODE_TYPE_VIO  1
37 #define NODE_TYPE_SLOT 2
38 #define NODE_TYPE_PHB  3
39
40 static struct device_node *find_vio_slot_node(char *drc_name)
41 {
42         struct device_node *parent = of_find_node_by_name(NULL, "vdevice");
43         struct device_node *dn = NULL;
44         int rc;
45
46         if (!parent)
47                 return NULL;
48
49         while ((dn = of_get_next_child(parent, dn))) {
50                 rc = rpaphp_check_drc_props(dn, drc_name, NULL);
51                 if (rc == 0)
52                         break;
53         }
54         of_node_put(parent);
55
56         return dn;
57 }
58
59 /* Find dlpar-capable pci node that contains the specified name and type */
60 static struct device_node *find_php_slot_pci_node(char *drc_name,
61                                                   char *drc_type)
62 {
63         struct device_node *np = NULL;
64         int rc;
65
66         while ((np = of_find_node_by_name(np, "pci"))) {
67                 rc = rpaphp_check_drc_props(np, drc_name, drc_type);
68                 if (rc == 0)
69                         break;
70         }
71
72         return np;
73 }
74
75 /* Returns a device_node with its reference count incremented */
76 static struct device_node *find_dlpar_node(char *drc_name, int *node_type)
77 {
78         struct device_node *dn;
79
80         dn = find_php_slot_pci_node(drc_name, "SLOT");
81         if (dn) {
82                 *node_type = NODE_TYPE_SLOT;
83                 return dn;
84         }
85
86         dn = find_php_slot_pci_node(drc_name, "PHB");
87         if (dn) {
88                 *node_type = NODE_TYPE_PHB;
89                 return dn;
90         }
91
92         dn = find_vio_slot_node(drc_name);
93         if (dn) {
94                 *node_type = NODE_TYPE_VIO;
95                 return dn;
96         }
97
98         return NULL;
99 }
100
101 /**
102  * find_php_slot - return hotplug slot structure for device node
103  * @dn: target &device_node
104  *
105  * This routine will return the hotplug slot structure
106  * for a given device node. Note that built-in PCI slots
107  * may be dlpar-able, but not hot-pluggable, so this routine
108  * will return NULL for built-in PCI slots.
109  */
110 static struct slot *find_php_slot(struct device_node *dn)
111 {
112         struct slot *slot, *next;
113
114         list_for_each_entry_safe(slot, next, &rpaphp_slot_head,
115                                  rpaphp_slot_list) {
116                 if (slot->dn == dn)
117                         return slot;
118         }
119
120         return NULL;
121 }
122
123 static struct pci_dev *dlpar_find_new_dev(struct pci_bus *parent,
124                                         struct device_node *dev_dn)
125 {
126         struct pci_dev *tmp = NULL;
127         struct device_node *child_dn;
128
129         list_for_each_entry(tmp, &parent->devices, bus_list) {
130                 child_dn = pci_device_to_OF_node(tmp);
131                 if (child_dn == dev_dn)
132                         return tmp;
133         }
134         return NULL;
135 }
136
137 static void dlpar_pci_add_bus(struct device_node *dn)
138 {
139         struct pci_dn *pdn = PCI_DN(dn);
140         struct pci_controller *phb = pdn->phb;
141         struct pci_dev *dev = NULL;
142
143         eeh_add_device_tree_early(pdn);
144
145         /* Add EADS device to PHB bus, adding new entry to bus->devices */
146         dev = of_create_pci_dev(dn, phb->bus, pdn->devfn);
147         if (!dev) {
148                 printk(KERN_ERR "%s: failed to create pci dev for %pOF\n",
149                                 __func__, dn);
150                 return;
151         }
152
153         /* Scan below the new bridge */
154         if (pci_is_bridge(dev))
155                 of_scan_pci_bridge(dev);
156
157         /* Map IO space for child bus, which may or may not succeed */
158         pcibios_map_io_space(dev->subordinate);
159
160         /* Finish adding it : resource allocation, adding devices, etc...
161          * Note that we need to perform the finish pass on the -parent-
162          * bus of the EADS bridge so the bridge device itself gets
163          * properly added
164          */
165         pcibios_finish_adding_to_bus(phb->bus);
166 }
167
168 static int dlpar_add_pci_slot(char *drc_name, struct device_node *dn)
169 {
170         struct pci_dev *dev;
171         struct pci_controller *phb;
172
173         if (pci_find_bus_by_node(dn))
174                 return -EINVAL;
175
176         /* Add pci bus */
177         dlpar_pci_add_bus(dn);
178
179         /* Confirm new bridge dev was created */
180         phb = PCI_DN(dn)->phb;
181         dev = dlpar_find_new_dev(phb->bus, dn);
182
183         if (!dev) {
184                 printk(KERN_ERR "%s: unable to add bus %s\n", __func__,
185                         drc_name);
186                 return -EIO;
187         }
188
189         if (dev->hdr_type != PCI_HEADER_TYPE_BRIDGE) {
190                 printk(KERN_ERR "%s: unexpected header type %d, unable to add bus %s\n",
191                         __func__, dev->hdr_type, drc_name);
192                 return -EIO;
193         }
194
195         /* Add hotplug slot */
196         if (rpaphp_add_slot(dn)) {
197                 printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
198                         __func__, drc_name);
199                 return -EIO;
200         }
201         return 0;
202 }
203
204 static int dlpar_remove_phb(char *drc_name, struct device_node *dn)
205 {
206         struct slot *slot;
207         struct pci_dn *pdn;
208         int rc = 0;
209
210         if (!pci_find_bus_by_node(dn))
211                 return -EINVAL;
212
213         /* If pci slot is hotpluggable, use hotplug to remove it */
214         slot = find_php_slot(dn);
215         if (slot && rpaphp_deregister_slot(slot)) {
216                 printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
217                        __func__, drc_name);
218                 return -EIO;
219         }
220
221         pdn = dn->data;
222         BUG_ON(!pdn || !pdn->phb);
223         rc = remove_phb_dynamic(pdn->phb);
224         if (rc < 0)
225                 return rc;
226
227         pdn->phb = NULL;
228
229         return 0;
230 }
231
232 static int dlpar_add_phb(char *drc_name, struct device_node *dn)
233 {
234         struct pci_controller *phb;
235
236         if (PCI_DN(dn) && PCI_DN(dn)->phb) {
237                 /* PHB already exists */
238                 return -EINVAL;
239         }
240
241         phb = init_phb_dynamic(dn);
242         if (!phb)
243                 return -EIO;
244
245         if (rpaphp_add_slot(dn)) {
246                 printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
247                         __func__, drc_name);
248                 return -EIO;
249         }
250         return 0;
251 }
252
253 static int dlpar_add_vio_slot(char *drc_name, struct device_node *dn)
254 {
255         struct vio_dev *vio_dev;
256
257         vio_dev = vio_find_node(dn);
258         if (vio_dev) {
259                 put_device(&vio_dev->dev);
260                 return -EINVAL;
261         }
262
263         if (!vio_register_device_node(dn)) {
264                 printk(KERN_ERR
265                         "%s: failed to register vio node %s\n",
266                         __func__, drc_name);
267                 return -EIO;
268         }
269         return 0;
270 }
271
272 /**
273  * dlpar_add_slot - DLPAR add an I/O Slot
274  * @drc_name: drc-name of newly added slot
275  *
276  * Make the hotplug module and the kernel aware of a newly added I/O Slot.
277  * Return Codes:
278  * 0                    Success
279  * -ENODEV              Not a valid drc_name
280  * -EINVAL              Slot already added
281  * -ERESTARTSYS         Signalled before obtaining lock
282  * -EIO                 Internal PCI Error
283  */
284 int dlpar_add_slot(char *drc_name)
285 {
286         struct device_node *dn = NULL;
287         int node_type;
288         int rc = -EIO;
289
290         if (mutex_lock_interruptible(&rpadlpar_mutex))
291                 return -ERESTARTSYS;
292
293         /* Find newly added node */
294         dn = find_dlpar_node(drc_name, &node_type);
295         if (!dn) {
296                 rc = -ENODEV;
297                 goto exit;
298         }
299
300         switch (node_type) {
301                 case NODE_TYPE_VIO:
302                         rc = dlpar_add_vio_slot(drc_name, dn);
303                         break;
304                 case NODE_TYPE_SLOT:
305                         rc = dlpar_add_pci_slot(drc_name, dn);
306                         break;
307                 case NODE_TYPE_PHB:
308                         rc = dlpar_add_phb(drc_name, dn);
309                         break;
310         }
311         of_node_put(dn);
312
313         printk(KERN_INFO "%s: slot %s added\n", DLPAR_MODULE_NAME, drc_name);
314 exit:
315         mutex_unlock(&rpadlpar_mutex);
316         return rc;
317 }
318
319 /**
320  * dlpar_remove_vio_slot - DLPAR remove a virtual I/O Slot
321  * @drc_name: drc-name of newly added slot
322  * @dn: &device_node
323  *
324  * Remove the kernel and hotplug representations of an I/O Slot.
325  * Return Codes:
326  * 0                    Success
327  * -EINVAL              Vio dev doesn't exist
328  */
329 static int dlpar_remove_vio_slot(char *drc_name, struct device_node *dn)
330 {
331         struct vio_dev *vio_dev;
332
333         vio_dev = vio_find_node(dn);
334         if (!vio_dev)
335                 return -EINVAL;
336
337         vio_unregister_device(vio_dev);
338
339         put_device(&vio_dev->dev);
340
341         return 0;
342 }
343
344 /**
345  * dlpar_remove_pci_slot - DLPAR remove a PCI I/O Slot
346  * @drc_name: drc-name of newly added slot
347  * @dn: &device_node
348  *
349  * Remove the kernel and hotplug representations of a PCI I/O Slot.
350  * Return Codes:
351  * 0                    Success
352  * -ENODEV              Not a valid drc_name
353  * -EIO                 Internal PCI Error
354  */
355 int dlpar_remove_pci_slot(char *drc_name, struct device_node *dn)
356 {
357         struct pci_bus *bus;
358         struct slot *slot;
359         int ret = 0;
360
361         pci_lock_rescan_remove();
362
363         bus = pci_find_bus_by_node(dn);
364         if (!bus) {
365                 ret = -EINVAL;
366                 goto out;
367         }
368
369         pr_debug("PCI: Removing PCI slot below EADS bridge %s\n",
370                  bus->self ? pci_name(bus->self) : "<!PHB!>");
371
372         slot = find_php_slot(dn);
373         if (slot) {
374                 pr_debug("PCI: Removing hotplug slot for %04x:%02x...\n",
375                          pci_domain_nr(bus), bus->number);
376
377                 if (rpaphp_deregister_slot(slot)) {
378                         printk(KERN_ERR
379                                 "%s: unable to remove hotplug slot %s\n",
380                                 __func__, drc_name);
381                         ret = -EIO;
382                         goto out;
383                 }
384         }
385
386         /* Remove all devices below slot */
387         pci_hp_remove_devices(bus);
388
389         /* Unmap PCI IO space */
390         if (pcibios_unmap_io_space(bus)) {
391                 printk(KERN_ERR "%s: failed to unmap bus range\n",
392                         __func__);
393                 ret = -ERANGE;
394                 goto out;
395         }
396
397         /* Remove the EADS bridge device itself */
398         BUG_ON(!bus->self);
399         pr_debug("PCI: Now removing bridge device %s\n", pci_name(bus->self));
400         pci_stop_and_remove_bus_device(bus->self);
401
402  out:
403         pci_unlock_rescan_remove();
404         return ret;
405 }
406
407 /**
408  * dlpar_remove_slot - DLPAR remove an I/O Slot
409  * @drc_name: drc-name of newly added slot
410  *
411  * Remove the kernel and hotplug representations of an I/O Slot.
412  * Return Codes:
413  * 0                    Success
414  * -ENODEV              Not a valid drc_name
415  * -EINVAL              Slot already removed
416  * -ERESTARTSYS         Signalled before obtaining lock
417  * -EIO                 Internal Error
418  */
419 int dlpar_remove_slot(char *drc_name)
420 {
421         struct device_node *dn;
422         int node_type;
423         int rc = 0;
424
425         if (mutex_lock_interruptible(&rpadlpar_mutex))
426                 return -ERESTARTSYS;
427
428         dn = find_dlpar_node(drc_name, &node_type);
429         if (!dn) {
430                 rc = -ENODEV;
431                 goto exit;
432         }
433
434         switch (node_type) {
435                 case NODE_TYPE_VIO:
436                         rc = dlpar_remove_vio_slot(drc_name, dn);
437                         break;
438                 case NODE_TYPE_PHB:
439                         rc = dlpar_remove_phb(drc_name, dn);
440                         break;
441                 case NODE_TYPE_SLOT:
442                         rc = dlpar_remove_pci_slot(drc_name, dn);
443                         break;
444         }
445         of_node_put(dn);
446         vm_unmap_aliases();
447
448         printk(KERN_INFO "%s: slot %s removed\n", DLPAR_MODULE_NAME, drc_name);
449 exit:
450         mutex_unlock(&rpadlpar_mutex);
451         return rc;
452 }
453
454 static inline int is_dlpar_capable(void)
455 {
456         int rc = rtas_token("ibm,configure-connector");
457
458         return (int) (rc != RTAS_UNKNOWN_SERVICE);
459 }
460
461 int __init rpadlpar_io_init(void)
462 {
463
464         if (!is_dlpar_capable()) {
465                 printk(KERN_WARNING "%s: partition not DLPAR capable\n",
466                         __func__);
467                 return -EPERM;
468         }
469
470         return dlpar_sysfs_init();
471 }
472
473 void rpadlpar_io_exit(void)
474 {
475         dlpar_sysfs_exit();
476         return;
477 }
478
479 module_init(rpadlpar_io_init);
480 module_exit(rpadlpar_io_exit);
481 MODULE_LICENSE("GPL");