10                 (FMan) support
11
12 config DPAA_ERRATUM_A050385
13         bool
14         depends on ARM64 && FSL_DPAA
15         default y
16         help
17                 DPAA FMan erratum A050385 software workaround implementation:
18                 align buffers, data start, SG fragment length to avoid FMan DMA
19                 splits.
20                 FMAN DMA read or writes under heavy traffic load may cause FMAN
21                 internal resource leak thus stopping further packet processing.
22                 The FMAN internal queue can overflow when FMAN splits single
23                 read or write transactions into multiple smaller transactions
24                 such that more than 17 AXI transactions are in flight from FMAN
25                 to interconnect. When the FMAN internal queue overflows, it can
26                 stall further packet processing. The issue can occur with any
27                 one of the following three conditions:
28                 1. FMAN AXI transaction crosses 4K address boundary (Errata
29                 A010022)
30                 2. FMAN DMA address for an AXI transaction is not 16 byte
31                 aligned, i.e. the last 4 bits of an address are non-zero
32                 3. Scatter Gather (SG) frames have more than one SG buffer in
33                 the SG list and any one of the buffers, except the last
34                 buffer in the SG list has data size that is not a multiple
35                 of 16 bytes, i.e., other than 16, 32, 48, 64, etc.
36                 With any one of the above three conditions present, there is