GNU Linux-libre 5.10.153-gnu1
[releases.git] / drivers / net / Kconfig
1 # SPDX-License-Identifier: GPL-2.0-only
2 #
3 # Network device configuration
4 #
5
6 menuconfig NETDEVICES
7         default y if UML
8         depends on NET
9         bool "Network device support"
10         help
11           You can say N here if you don't intend to connect your Linux box to
12           any other computer at all.
13
14           You'll have to say Y if your computer contains a network card that
15           you want to use under Linux. If you are going to run SLIP or PPP over
16           telephone line or null modem cable you need say Y here. Connecting
17           two machines with parallel ports using PLIP needs this, as well as
18           AX.25/KISS for sending Internet traffic over amateur radio links.
19
20           See also "The Linux Network Administrator's Guide" by Olaf Kirch and
21           Terry Dawson. Available at <http://www.tldp.org/guides.html>.
22
23           If unsure, say Y.
24
25 # All the following symbols are dependent on NETDEVICES - do not repeat
26 # that for each of the symbols.
27 if NETDEVICES
28
29 config MII
30         tristate
31
32 config NET_CORE
33         default y
34         bool "Network core driver support"
35         help
36           You can say N here if you do not intend to use any of the
37           networking core drivers (i.e. VLAN, bridging, bonding, etc.)
38
39 if NET_CORE
40
41 config BONDING
42         tristate "Bonding driver support"
43         depends on INET
44         depends on IPV6 || IPV6=n
45         help
46           Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
47           Channels together. This is called 'Etherchannel' by Cisco,
48           'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
49
50           The driver supports multiple bonding modes to allow for both high
51           performance and high availability operation.
52
53           Refer to <file:Documentation/networking/bonding.rst> for more
54           information.
55
56           To compile this driver as a module, choose M here: the module
57           will be called bonding.
58
59 config DUMMY
60         tristate "Dummy net driver support"
61         help
62           This is essentially a bit-bucket device (i.e. traffic you send to
63           this device is consigned into oblivion) with a configurable IP
64           address. It is most commonly used in order to make your currently
65           inactive SLIP address seem like a real address for local programs.
66           If you use SLIP or PPP, you might want to say Y here. It won't
67           enlarge your kernel. What a deal. Read about it in the Network
68           Administrator's Guide, available from
69           <http://www.tldp.org/docs.html#guide>.
70
71           To compile this driver as a module, choose M here: the module
72           will be called dummy.
73
74 config WIREGUARD
75         tristate "WireGuard secure network tunnel"
76         depends on NET && INET
77         depends on IPV6 || !IPV6
78         select NET_UDP_TUNNEL
79         select DST_CACHE
80         select CRYPTO
81         select CRYPTO_LIB_CURVE25519
82         select CRYPTO_LIB_CHACHA20POLY1305
83         select CRYPTO_CHACHA20_X86_64 if X86 && 64BIT
84         select CRYPTO_POLY1305_X86_64 if X86 && 64BIT
85         select CRYPTO_BLAKE2S_X86 if X86 && 64BIT
86         select CRYPTO_CURVE25519_X86 if X86 && 64BIT
87         select ARM_CRYPTO if ARM
88         select ARM64_CRYPTO if ARM64
89         select CRYPTO_CHACHA20_NEON if ARM || (ARM64 && KERNEL_MODE_NEON)
90         select CRYPTO_POLY1305_NEON if ARM64 && KERNEL_MODE_NEON
91         select CRYPTO_POLY1305_ARM if ARM
92         select CRYPTO_CURVE25519_NEON if ARM && KERNEL_MODE_NEON
93         select CRYPTO_CHACHA_MIPS if CPU_MIPS32_R2
94         select CRYPTO_POLY1305_MIPS if MIPS
95         help
96           WireGuard is a secure, fast, and easy to use replacement for IPSec
97           that uses modern cryptography and clever networking tricks. It's
98           designed to be fairly general purpose and abstract enough to fit most
99           use cases, while at the same time remaining extremely simple to
100           configure. See www.wireguard.com for more info.
101
102           It's safe to say Y or M here, as the driver is very lightweight and
103           is only in use when an administrator chooses to add an interface.
104
105 config WIREGUARD_DEBUG
106         bool "Debugging checks and verbose messages"
107         depends on WIREGUARD
108         help
109           This will write log messages for handshake and other events
110           that occur for a WireGuard interface. It will also perform some
111           extra validation checks and unit tests at various points. This is
112           only useful for debugging.
113
114           Say N here unless you know what you're doing.
115
116 config EQUALIZER
117         tristate "EQL (serial line load balancing) support"
118         help
119           If you have two serial connections to some other computer (this
120           usually requires two modems and two telephone lines) and you use
121           SLIP (the protocol for sending Internet traffic over telephone
122           lines) or PPP (a better SLIP) on them, you can make them behave like
123           one double speed connection using this driver.  Naturally, this has
124           to be supported at the other end as well, either with a similar EQL
125           Linux driver or with a Livingston Portmaster 2e.
126
127           Say Y if you want this and read
128           <file:Documentation/networking/eql.rst>.  You may also want to read
129           section 6.2 of the NET-3-HOWTO, available from
130           <http://www.tldp.org/docs.html#howto>.
131
132           To compile this driver as a module, choose M here: the module
133           will be called eql.  If unsure, say N.
134
135 config NET_FC
136         bool "Fibre Channel driver support"
137         depends on SCSI && PCI
138         help
139           Fibre Channel is a high speed serial protocol mainly used to connect
140           large storage devices to the computer; it is compatible with and
141           intended to replace SCSI.
142
143           If you intend to use Fibre Channel, you need to have a Fibre channel
144           adaptor card in your computer; say Y here and to the driver for your
145           adaptor below. You also should have said Y to "SCSI support" and
146           "SCSI generic support".
147
148 config IFB
149         tristate "Intermediate Functional Block support"
150         depends on NET_ACT_MIRRED || NFT_FWD_NETDEV
151         select NET_REDIRECT
152         help
153           This is an intermediate driver that allows sharing of
154           resources.
155           To compile this driver as a module, choose M here: the module
156           will be called ifb.  If you want to use more than one ifb
157           device at a time, you need to compile this driver as a module.
158           Instead of 'ifb', the devices will then be called 'ifb0',
159           'ifb1' etc.
160           Look at the iproute2 documentation directory for usage etc
161
162 source "drivers/net/team/Kconfig"
163
164 config MACVLAN
165         tristate "MAC-VLAN support"
166         help
167           This allows one to create virtual interfaces that map packets to
168           or from specific MAC addresses to a particular interface.
169
170           Macvlan devices can be added using the "ip" command from the
171           iproute2 package starting with the iproute2-2.6.23 release:
172
173           "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
174
175           To compile this driver as a module, choose M here: the module
176           will be called macvlan.
177
178 config MACVTAP
179         tristate "MAC-VLAN based tap driver"
180         depends on MACVLAN
181         depends on INET
182         select TAP
183         help
184           This adds a specialized tap character device driver that is based
185           on the MAC-VLAN network interface, called macvtap. A macvtap device
186           can be added in the same way as a macvlan device, using 'type
187           macvtap', and then be accessed through the tap user space interface.
188
189           To compile this driver as a module, choose M here: the module
190           will be called macvtap.
191
192 config IPVLAN_L3S
193         depends on NETFILTER
194         depends on IPVLAN
195         def_bool y
196         select NET_L3_MASTER_DEV
197
198 config IPVLAN
199         tristate "IP-VLAN support"
200         depends on INET
201         depends on IPV6 || !IPV6
202         help
203           This allows one to create virtual devices off of a main interface
204           and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
205           on packets. All interfaces (including the main interface) share L2
206           making it transparent to the connected L2 switch.
207
208           Ipvlan devices can be added using the "ip" command from the
209           iproute2 package starting with the iproute2-3.19 release:
210
211           "ip link add link <main-dev> [ NAME ] type ipvlan"
212
213           To compile this driver as a module, choose M here: the module
214           will be called ipvlan.
215
216 config IPVTAP
217         tristate "IP-VLAN based tap driver"
218         depends on IPVLAN
219         depends on INET
220         select TAP
221         help
222           This adds a specialized tap character device driver that is based
223           on the IP-VLAN network interface, called ipvtap. An ipvtap device
224           can be added in the same way as a ipvlan device, using 'type
225           ipvtap', and then be accessed through the tap user space interface.
226
227           To compile this driver as a module, choose M here: the module
228           will be called ipvtap.
229
230 config VXLAN
231         tristate "Virtual eXtensible Local Area Network (VXLAN)"
232         depends on INET
233         select NET_UDP_TUNNEL
234         select GRO_CELLS
235         help
236           This allows one to create vxlan virtual interfaces that provide
237           Layer 2 Networks over Layer 3 Networks. VXLAN is often used
238           to tunnel virtual network infrastructure in virtualized environments.
239           For more information see:
240             http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
241
242           To compile this driver as a module, choose M here: the module
243           will be called vxlan.
244
245 config GENEVE
246         tristate "Generic Network Virtualization Encapsulation"
247         depends on INET
248         depends on IPV6 || !IPV6
249         select NET_UDP_TUNNEL
250         select GRO_CELLS
251         help
252           This allows one to create geneve virtual interfaces that provide
253           Layer 2 Networks over Layer 3 Networks. GENEVE is often used
254           to tunnel virtual network infrastructure in virtualized environments.
255           For more information see:
256             http://tools.ietf.org/html/draft-gross-geneve-02
257
258           To compile this driver as a module, choose M here: the module
259           will be called geneve.
260
261 config BAREUDP
262        tristate "Bare UDP Encapsulation"
263        depends on INET
264        depends on IPV6 || !IPV6
265        select NET_UDP_TUNNEL
266        select GRO_CELLS
267        help
268           This adds a bare UDP tunnel module for tunnelling different
269           kinds of traffic like MPLS, IP, etc. inside a UDP tunnel.
270
271           To compile this driver as a module, choose M here: the module
272           will be called bareudp.
273
274 config GTP
275         tristate "GPRS Tunneling Protocol datapath (GTP-U)"
276         depends on INET
277         select NET_UDP_TUNNEL
278         help
279           This allows one to create gtp virtual interfaces that provide
280           the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
281           is used to prevent subscribers from accessing mobile carrier core
282           network infrastructure. This driver requires a userspace software that
283           implements the signaling protocol (GTP-C) to update its PDP context
284           base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
285           tunneling protocol is implemented according to the GSM TS 09.60 and
286           3GPP TS 29.060 standards.
287
288           To compile this drivers as a module, choose M here: the module
289           wil be called gtp.
290
291 config MACSEC
292         tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
293         select CRYPTO
294         select CRYPTO_AES
295         select CRYPTO_GCM
296         select GRO_CELLS
297         help
298            MACsec is an encryption standard for Ethernet.
299
300 config NETCONSOLE
301         tristate "Network console logging support"
302         help
303           If you want to log kernel messages over the network, enable this.
304           See <file:Documentation/networking/netconsole.rst> for details.
305
306 config NETCONSOLE_DYNAMIC
307         bool "Dynamic reconfiguration of logging targets"
308         depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
309                         !(NETCONSOLE=y && CONFIGFS_FS=m)
310         help
311           This option enables the ability to dynamically reconfigure target
312           parameters (interface, IP addresses, port numbers, MAC addresses)
313           at runtime through a userspace interface exported using configfs.
314           See <file:Documentation/networking/netconsole.rst> for details.
315
316 config NETPOLL
317         def_bool NETCONSOLE
318         select SRCU
319
320 config NET_POLL_CONTROLLER
321         def_bool NETPOLL
322
323 config NTB_NETDEV
324         tristate "Virtual Ethernet over NTB Transport"
325         depends on NTB_TRANSPORT
326
327 config RIONET
328         tristate "RapidIO Ethernet over messaging driver support"
329         depends on RAPIDIO
330
331 config RIONET_TX_SIZE
332         int "Number of outbound queue entries"
333         depends on RIONET
334         default "128"
335
336 config RIONET_RX_SIZE
337         int "Number of inbound queue entries"
338         depends on RIONET
339         default "128"
340
341 config TUN
342         tristate "Universal TUN/TAP device driver support"
343         depends on INET
344         select CRC32
345         help
346           TUN/TAP provides packet reception and transmission for user space
347           programs.  It can be viewed as a simple Point-to-Point or Ethernet
348           device, which instead of receiving packets from a physical media,
349           receives them from user space program and instead of sending packets
350           via physical media writes them to the user space program.
351
352           When a program opens /dev/net/tun, driver creates and registers
353           corresponding net device tunX or tapX.  After a program closed above
354           devices, driver will automatically delete tunXX or tapXX device and
355           all routes corresponding to it.
356
357           Please read <file:Documentation/networking/tuntap.rst> for more
358           information.
359
360           To compile this driver as a module, choose M here: the module
361           will be called tun.
362
363           If you don't know what to use this for, you don't need it.
364
365 config TAP
366         tristate
367         help
368           This option is selected by any driver implementing tap user space
369           interface for a virtual interface to re-use core tap functionality.
370
371 config TUN_VNET_CROSS_LE
372         bool "Support for cross-endian vnet headers on little-endian kernels"
373         default n
374         help
375           This option allows TUN/TAP and MACVTAP device drivers in a
376           little-endian kernel to parse vnet headers that come from a
377           big-endian legacy virtio device.
378
379           Userspace programs can control the feature using the TUNSETVNETBE
380           and TUNGETVNETBE ioctls.
381
382           Unless you have a little-endian system hosting a big-endian virtual
383           machine with a legacy virtio NIC, you should say N.
384
385 config VETH
386         tristate "Virtual ethernet pair device"
387         help
388           This device is a local ethernet tunnel. Devices are created in pairs.
389           When one end receives the packet it appears on its pair and vice
390           versa.
391
392 config VIRTIO_NET
393         tristate "Virtio network driver"
394         depends on VIRTIO
395         select NET_FAILOVER
396         help
397           This is the virtual network driver for virtio.  It can be used with
398           QEMU based VMMs (like KVM or Xen).  Say Y or M.
399
400 config NLMON
401         tristate "Virtual netlink monitoring device"
402         help
403           This option enables a monitoring net device for netlink skbs. The
404           purpose of this is to analyze netlink messages with packet sockets.
405           Thus applications like tcpdump will be able to see local netlink
406           messages if they tap into the netlink device, record pcaps for further
407           diagnostics, etc. This is mostly intended for developers or support
408           to debug netlink issues. If unsure, say N.
409
410 config NET_VRF
411         tristate "Virtual Routing and Forwarding (Lite)"
412         depends on IP_MULTIPLE_TABLES
413         depends on NET_L3_MASTER_DEV
414         depends on IPV6 || IPV6=n
415         depends on IPV6_MULTIPLE_TABLES || IPV6=n
416         help
417           This option enables the support for mapping interfaces into VRF's. The
418           support enables VRF devices.
419
420 config VSOCKMON
421         tristate "Virtual vsock monitoring device"
422         depends on VHOST_VSOCK
423         help
424           This option enables a monitoring net device for vsock sockets. It is
425           mostly intended for developers or support to debug vsock issues. If
426           unsure, say N.
427
428 endif # NET_CORE
429
430 config SUNGEM_PHY
431         tristate
432
433 source "drivers/net/arcnet/Kconfig"
434
435 source "drivers/atm/Kconfig"
436
437 source "drivers/net/caif/Kconfig"
438
439 source "drivers/net/dsa/Kconfig"
440
441 source "drivers/net/ethernet/Kconfig"
442
443 source "drivers/net/fddi/Kconfig"
444
445 source "drivers/net/hippi/Kconfig"
446
447 source "drivers/net/ipa/Kconfig"
448
449 config NET_SB1000
450         tristate "General Instruments Surfboard 1000"
451         depends on PNP
452         help
453           This is a driver for the General Instrument (also known as
454           NextLevel) SURFboard 1000 internal
455           cable modem. This is an ISA card which is used by a number of cable
456           TV companies to provide cable modem access. It's a one-way
457           downstream-only cable modem, meaning that your upstream net link is
458           provided by your regular phone modem.
459
460           At present this driver only compiles as a module, so say M here if
461           you have this card. The module will be called sb1000. Then read
462           <file:Documentation/networking/device_drivers/cable/sb1000.rst> for
463           information on how to use this module, as it needs special ppp
464           scripts for establishing a connection. Further documentation
465           and the necessary scripts can be found at:
466
467           <http://www.jacksonville.net/~fventuri/>
468           <http://home.adelphia.net/~siglercm/sb1000.html>
469           <http://linuxpower.cx/~cable/>
470
471           If you don't have this card, of course say N.
472
473 source "drivers/net/phy/Kconfig"
474
475 source "drivers/net/mdio/Kconfig"
476
477 source "drivers/net/pcs/Kconfig"
478
479 source "drivers/net/plip/Kconfig"
480
481 source "drivers/net/ppp/Kconfig"
482
483 source "drivers/net/slip/Kconfig"
484
485 source "drivers/s390/net/Kconfig"
486
487 source "drivers/net/usb/Kconfig"
488
489 source "drivers/net/wireless/Kconfig"
490
491 source "drivers/net/wimax/Kconfig"
492
493 source "drivers/net/wan/Kconfig"
494
495 source "drivers/net/ieee802154/Kconfig"
496
497 config XEN_NETDEV_FRONTEND
498         tristate "Xen network device frontend driver"
499         depends on XEN
500         select XEN_XENBUS_FRONTEND
501         select PAGE_POOL
502         default y
503         help
504           This driver provides support for Xen paravirtual network
505           devices exported by a Xen network driver domain (often
506           domain 0).
507
508           The corresponding Linux backend driver is enabled by the
509           CONFIG_XEN_NETDEV_BACKEND option.
510
511           If you are compiling a kernel for use as Xen guest, you
512           should say Y here. To compile this driver as a module, chose
513           M here: the module will be called xen-netfront.
514
515 config XEN_NETDEV_BACKEND
516         tristate "Xen backend network device"
517         depends on XEN_BACKEND
518         help
519           This driver allows the kernel to act as a Xen network driver
520           domain which exports paravirtual network devices to other
521           Xen domains. These devices can be accessed by any operating
522           system that implements a compatible front end.
523
524           The corresponding Linux frontend driver is enabled by the
525           CONFIG_XEN_NETDEV_FRONTEND configuration option.
526
527           The backend driver presents a standard network device
528           endpoint for each paravirtual network device to the driver
529           domain network stack. These can then be bridged or routed
530           etc in order to provide full network connectivity.
531
532           If you are compiling a kernel to run in a Xen network driver
533           domain (often this is domain 0) you should say Y here. To
534           compile this driver as a module, chose M here: the module
535           will be called xen-netback.
536
537 config VMXNET3
538         tristate "VMware VMXNET3 ethernet driver"
539         depends on PCI && INET
540         depends on !(PAGE_SIZE_64KB || ARM64_64K_PAGES || \
541                      IA64_PAGE_SIZE_64KB || MICROBLAZE_64K_PAGES || \
542                      PARISC_PAGE_SIZE_64KB || PPC_64K_PAGES)
543         help
544           This driver supports VMware's vmxnet3 virtual ethernet NIC.
545           To compile this driver as a module, choose M here: the
546           module will be called vmxnet3.
547
548 config FUJITSU_ES
549         tristate "FUJITSU Extended Socket Network Device driver"
550         depends on ACPI
551         help
552           This driver provides support for Extended Socket network device
553           on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.
554
555 config USB4_NET
556         tristate "Networking over USB4 and Thunderbolt cables"
557         depends on USB4 && INET
558         help
559           Select this if you want to create network between two computers
560           over a USB4 and Thunderbolt cables. The driver supports Apple
561           ThunderboltIP protocol and allows communication with any host
562           supporting the same protocol including Windows and macOS.
563
564           To compile this driver a module, choose M here. The module will be
565           called thunderbolt-net.
566
567 source "drivers/net/hyperv/Kconfig"
568
569 config NETDEVSIM
570         tristate "Simulated networking device"
571         depends on DEBUG_FS
572         depends on INET
573         depends on IPV6 || IPV6=n
574         select NET_DEVLINK
575         help
576           This driver is a developer testing tool and software model that can
577           be used to test various control path networking APIs, especially
578           HW-offload related.
579
580           To compile this driver as a module, choose M here: the module
581           will be called netdevsim.
582
583 config NET_FAILOVER
584         tristate "Failover driver"
585         select FAILOVER
586         help
587           This provides an automated failover mechanism via APIs to create
588           and destroy a failover master netdev and manages a primary and
589           standby slave netdevs that get registered via the generic failover
590           infrastructure. This can be used by paravirtual drivers to enable
591           an alternate low latency datapath. It also enables live migration of
592           a VM with direct attached VF by failing over to the paravirtual
593           datapath when the VF is unplugged.
594
595 endif # NETDEVICES