1 /* SPDX-License-Identifier: GPL-2.0 */
2 #ifndef _SCD30_H
3 #define _SCD30_H
4
5 #include <linux/completion.h>
6 #include <linux/device.h>
7 #include <linux/mutex.h>
8 #include <linux/pm.h>
9 #include <linux/regulator/consumer.h>
10 #include <linux/types.h>
11
12 struct scd30_state;
13
14 enum scd30_cmd {
15         /* start continuous measurement with pressure compensation */
16         CMD_START_MEAS,
17         /* stop continuous measurement */
18         CMD_STOP_MEAS,
19         /* set/get measurement interval */
20         CMD_MEAS_INTERVAL,
21         /* check whether new measurement is ready */
22         CMD_MEAS_READY,
23         /* get measurement */
24         CMD_READ_MEAS,
25         /* turn on/off automatic self calibration */
26         CMD_ASC,
27         /* set/get forced recalibration value */
28         CMD_FRC,
29         /* set/get temperature offset */
30         CMD_TEMP_OFFSET,
31         /* get firmware version */
32         CMD_FW_VERSION,
33         /* reset sensor */
34         CMD_RESET,
35         /*
36          * Command for altitude compensation was omitted intentionally because
37          * the same can be achieved by means of CMD_START_MEAS which takes
38          * pressure above the sea level as an argument.
39          */
40 };
41
42 #define SCD30_MEAS_COUNT 3
43
44 typedef int (*scd30_command_t)(struct scd30_state *state, enum scd30_cmd cmd, u16 arg,
45                                void *response, int size);
46
47 struct scd30_state {
48         /* serialize access to the device */
49         struct mutex lock;
50         struct device *dev;
51         struct regulator *vdd;
52         struct completion meas_ready;
53         /*
54          * priv pointer is solely for serdev driver private data. We keep it
55          * here because driver_data inside dev has been already used for iio and
56          * struct serdev_device doesn't have one.
57          */
58         void *priv;
59         int irq;
60         /*
61          * no way to retrieve current ambient pressure compensation value from
62          * the sensor so keep one around
63          */
64         u16 pressure_comp;
65         u16 meas_interval;
66         int meas[SCD30_MEAS_COUNT];
67
68         scd30_command_t command;
69 };
70
71 int scd30_suspend(struct device *dev);
72 int scd30_resume(struct device *dev);
73
74 static __maybe_unused SIMPLE_DEV_PM_OPS(scd30_pm_ops, scd30_suspend, scd30_resume);
75
76 int scd30_probe(struct device *dev, int irq, const char *name, void *priv, scd30_command_t command);