5 * SMSC / Microchip EMC1402, EMC1412
6 Addresses scanned: I2C 0x18, 0x1c, 0x29, 0x4c, 0x4d, 0x5c
9 http://ww1.microchip.com/downloads/en/DeviceDoc/1412.pdf
10 http://ww1.microchip.com/downloads/en/DeviceDoc/1402.pdf
11 * SMSC / Microchip EMC1403, EMC1404, EMC1413, EMC1414
12 Addresses scanned: I2C 0x18, 0x29, 0x4c, 0x4d
13 Prefix: 'emc1403', 'emc1404'
15 http://ww1.microchip.com/downloads/en/DeviceDoc/1403_1404.pdf
16 http://ww1.microchip.com/downloads/en/DeviceDoc/1413_1414.pdf
17 * SMSC / Microchip EMC1422
18 Addresses scanned: I2C 0x4c
21 http://ww1.microchip.com/downloads/en/DeviceDoc/1422.pdf
22 * SMSC / Microchip EMC1423, EMC1424
23 Addresses scanned: I2C 0x4c
24 Prefix: 'emc1423', 'emc1424'
26 http://ww1.microchip.com/downloads/en/DeviceDoc/1423_1424.pdf
29 Kalhan Trisal <kalhan.trisal@intel.com
35 The Standard Microsystems Corporation (SMSC) / Microchip EMC14xx chips
36 contain up to four temperature sensors. EMC14x2 support two sensors
37 (one internal, one external). EMC14x3 support three sensors (one internal,
38 two external), and EMC14x4 support four sensors (one internal, three
41 The chips implement three limits for each sensor: low (tempX_min), high
42 (tempX_max) and critical (tempX_crit.) The chips also implement an
43 hysteresis mechanism which applies to all limits. The relative difference
44 is stored in a single register on the chip, which means that the relative
45 difference between the limit and its hysteresis is always the same for
48 This implementation detail implies the following:
49 * When setting a limit, its hysteresis will automatically follow, the
50 difference staying unchanged. For example, if the old critical limit
51 was 80 degrees C, and the hysteresis was 75 degrees C, and you change
52 the critical limit to 90 degrees C, then the hysteresis will
53 automatically change to 85 degrees C.
54 * The hysteresis values can't be set independently. We decided to make
55 only temp1_crit_hyst writable, while all other hysteresis attributes
56 are read-only. Setting temp1_crit_hyst writes the difference between
57 temp1_crit_hyst and temp1_crit into the chip, and the same relative
58 hysteresis applies automatically to all other limits.
59 * The limits should be set before the hysteresis.