1 .. SPDX-License-Identifier: GPL-2.0
2
3 The cx88 driver
4 ===============
5
6 Author:  Gerd Hoffmann
7
8 Documentation missing at the cx88 datasheet
9 -------------------------------------------
10
11 MO_OUTPUT_FORMAT (0x310164)
12
13 .. code-block:: none
14
15   Previous default from DScaler: 0x1c1f0008
16   Digit 8: 31-28
17   28: PREVREMOD = 1
18
19   Digit 7: 27-24 (0xc = 12 = b1100 )
20   27: COMBALT = 1
21   26: PAL_INV_PHASE
22     (DScaler apparently set this to 1, resulted in sucky picture)
23
24   Digits 6,5: 23-16
25   25-16: COMB_RANGE = 0x1f [default] (9 bits -> max 512)
26
27   Digit 4: 15-12
28   15: DISIFX = 0
29   14: INVCBF = 0
30   13: DISADAPT = 0
31   12: NARROWADAPT = 0
32
33   Digit 3: 11-8
34   11: FORCE2H
35   10: FORCEREMD
36   9: NCHROMAEN
37   8: NREMODEN
38
39   Digit 2: 7-4
40   7-6: YCORE
41   5-4: CCORE
42
43   Digit 1: 3-0
44   3: RANGE = 1
45   2: HACTEXT
46   1: HSFMT
47
48 0x47 is the sync byte for MPEG-2 transport stream packets.
49 Datasheet incorrectly states to use 47 decimal. 188 is the length.
50 All DVB compliant frontends output packets with this start code.
51
52 Hauppauge WinTV cx88 IR information
53 -----------------------------------
54
55 The controls for the mux are GPIO [0,1] for source, and GPIO 2 for muting.
56
57 ====== ======== =================================================
58 GPIO0  GPIO1
59 ====== ======== =================================================
60   0        0    TV Audio
61   1        0    FM radio
62   0        1    Line-In
63   1        1    Mono tuner bypass or CD passthru (tuner specific)
64 ====== ======== =================================================
65
66 GPIO 16(I believe) is tied to the IR port (if present).
67
68
69 From the data sheet:
70
71 - Register 24'h20004  PCI Interrupt Status
72
73  - bit [18]  IR_SMP_INT Set when 32 input samples have been collected over
74  - gpio[16] pin into GP_SAMPLE register.
75
76 What's missing from the data sheet:
77
78 - Setup 4KHz sampling rate (roughly 2x oversampled; good enough for our RC5
79   compat remote)
80 - set register 0x35C050 to  0xa80a80
81 - enable sampling
82 - set register 0x35C054 to 0x5
83 - enable the IRQ bit 18 in the interrupt mask register (and
84   provide for a handler)
85
86 GP_SAMPLE register is at 0x35C058
87
88 Bits are then right shifted into the GP_SAMPLE register at the specified
89 rate; you get an interrupt when a full DWORD is received.
90 You need to recover the actual RC5 bits out of the (oversampled) IR sensor
91 bits. (Hint: look for the 0/1and 1/0 crossings of the RC5 bi-phase data)  An
92 actual raw RC5 code will span 2-3 DWORDS, depending on the actual alignment.
93
94 I'm pretty sure when no IR signal is present the receiver is always in a
95 marking state(1); but stray light, etc can cause intermittent noise values
96 as well.  Remember, this is a free running sample of the IR receiver state
97 over time, so don't assume any sample starts at any particular place.
98
99 Additional info
100 ~~~~~~~~~~~~~~~
101
102 This data sheet (google search) seems to have a lovely description of the
103 RC5 basics:
104 http://www.atmel.com/dyn/resources/prod_documents/doc2817.pdf
105
106 This document has more data:
107 http://www.nenya.be/beor/electronics/rc5.htm
108
109 This document has a  how to decode a bi-phase data stream:
110 http://www.ee.washington.edu/circuit_archive/text/ir_decode.txt
111