1 *ImgTec PowerDown Controller (PDC) Watchdog Timer (WDT)
4 - compatible : Should be "img,pdc-wdt"
5 - reg : Should contain WDT registers location and length
6 - clocks: Must contain an entry for each entry in clock-names.
7 - clock-names: Should contain "wdt" and "sys"; the watchdog counter
8 clock and register interface clock respectively.
9 - interrupts : Should contain WDT interrupt
14 compatible = "img,pdc-wdt";
15 reg = <0x18102100 0x100>;
16 clocks = <&pdc_wdt_clk>, <&sys_clk>;
17 clock-names = "wdt", "sys";
18 interrupts = <0 52 IRQ_TYPE_LEVEL_HIGH>;