1 * ST-Ericsson DB8500 Thermal
3 ** Thermal node properties:
5 - compatible : "stericsson,db8500-thermal";
6 - reg : address range of the thermal sensor registers;
7 - interrupts : interrupts generated from PRCMU;
8 - interrupt-names : "IRQ_HOTMON_LOW" and "IRQ_HOTMON_HIGH";
9 - num-trips : number of total trip points, this is required, set it 0 if none,
10 if greater than 0, the following properties must be defined;
11 - tripN-temp : temperature of trip point N, should be in ascending order;
12 - tripN-type : type of trip point N, should be one of "active" "passive" "hot"
14 - tripN-cdev-num : number of the cooling devices which can be bound to trip
15 point N, this is required if trip point N is defined, set it 0 if none,
16 otherwise the following cooling device names must be defined;
17 - tripN-cdev-nameM : name of the No. M cooling device of trip point N;
19 Usually the num-trips and tripN-*** are separated in board related dts files.
23 compatible = "stericsson,db8500-thermal";
24 reg = <0x801573c0 0x40>;
25 interrupts = <21 0x4>, <22 0x4>;
26 interrupt-names = "IRQ_HOTMON_LOW", "IRQ_HOTMON_HIGH";
31 trip0-type = "active";
33 trip0-cdev-name0 = "thermal-cpufreq-0";
36 trip1-type = "active";
38 trip1-cdev-name0 = "thermal-cpufreq-0";
39 trip1-cdev-name1 = "thermal-fan";
42 trip2-type = "critical";