5 $schema: http://devicetree.org/meta-schemas/core.yaml#
6
7 title: Voltage/Current Regulators
8
9 maintainers:
10   - Liam Girdwood <lgirdwood@gmail.com>
11   - Mark Brown <broonie@kernel.org>
12
13 properties:
14   regulator-name:
15     description: A string used as a descriptive name for regulator outputs
16     $ref: "/schemas/types.yaml#/definitions/string"
17
18   regulator-min-microvolt:
19     description: smallest voltage consumers may set
20
21   regulator-max-microvolt:
22     description: largest voltage consumers may set
23
24   regulator-microvolt-offset:
25     description: Offset applied to voltages to compensate for voltage drops
26     $ref: "/schemas/types.yaml#/definitions/uint32"
27
28   regulator-min-microamp:
29     description: smallest current consumers may set
30
31   regulator-max-microamp:
32     description: largest current consumers may set
33
34   regulator-input-current-limit-microamp:
35     description: maximum input current regulator allows
36
37   regulator-always-on:
38     description: boolean, regulator should never be disabled
39     type: boolean
40
41   regulator-boot-on:
42     description: bootloader/firmware enabled regulator.
43       It's expected that this regulator was left on by the bootloader.
44       If the bootloader didn't leave it on then OS should turn it on
45       at boot but shouldn't prevent it from being turned off later.
46       This property is intended to only be used for regulators where
47       software cannot read the state of the regulator.
48     type: boolean
49
50   regulator-allow-bypass:
51     description: allow the regulator to go into bypass mode
52     type: boolean
53
54   regulator-allow-set-load:
55     description: allow the regulator performance level to be configured
56     type: boolean
57
58   regulator-ramp-delay:
59     description: ramp delay for regulator(in uV/us) For hardware which supports
60       disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
61       = <0>) for disabling ramp delay.
62     $ref: "/schemas/types.yaml#/definitions/uint32"
63
64   regulator-enable-ramp-delay:
65     description: The time taken, in microseconds, for the supply rail to
66       reach the target voltage, plus/minus whatever tolerance the board
67       design requires. This property describes the total system ramp time
68       required due to the combination of internal ramping of the regulator
69       itself, and board design issues such as trace capacitance and load
70       on the supply.
71     $ref: "/schemas/types.yaml#/definitions/uint32"
72
73   regulator-settling-time-us:
74     description: Settling time, in microseconds, for voltage change if regulator
75       have the constant time for any level voltage change. This is useful
76       when regulator have exponential voltage change.
77
78   regulator-settling-time-up-us:
79     description: Settling time, in microseconds, for voltage increase if
80       the regulator needs a constant time to settle after voltage increases
81       of any level. This is useful for regulators with exponential voltage
82       changes.
83
84   regulator-settling-time-down-us:
85     description: Settling time, in microseconds, for voltage decrease if
86       the regulator needs a constant time to settle after voltage decreases
87       of any level. This is useful for regulators with exponential voltage
88       changes.
89
90   regulator-soft-start:
91     description: Enable soft start so that voltage ramps slowly
92     type: boolean
93
94   regulator-initial-mode:
95     description: initial operating mode. The set of possible operating modes
96       depends on the capabilities of every hardware so each device binding
97       documentation explains which values the regulator supports.
98     $ref: "/schemas/types.yaml#/definitions/uint32"
99
100   regulator-allowed-modes:
101     description: list of operating modes that software is allowed to configure
102       for the regulator at run-time.  Elements may be specified in any order.
103       The set of possible operating modes depends on the capabilities of
104       every hardware so each device binding document explains which values
105       the regulator supports.
106     $ref: "/schemas/types.yaml#/definitions/uint32-array"
107
108   regulator-system-load:
109     description: Load in uA present on regulator that is not captured by
110       any consumer request.
111     $ref: "/schemas/types.yaml#/definitions/uint32"
112
113   regulator-pull-down:
114     description: Enable pull down resistor when the regulator is disabled.
115     type: boolean
116
117   regulator-over-current-protection:
118     description: Enable over current protection.
119     type: boolean
120
121   regulator-oc-protection-microamp:
122     description: Set over current protection limit. This is a limit where
123       hardware performs emergency shutdown. Zero can be passed to disable
124       protection and value '1' indicates that protection should be enabled but
125       limit setting can be omitted.
126
127   regulator-oc-error-microamp:
128     description: Set over current error limit. This is a limit where part of
129       the hardware propably is malfunctional and damage prevention is requested.
130       Zero can be passed to disable error detection and value '1' indicates
131       that detection should be enabled but limit setting can be omitted.
132
133   regulator-oc-warn-microamp:
134     description: Set over current warning limit. This is a limit where hardware
135       is assumed still to be functional but approaching limit where it gets
136       damaged. Recovery actions should be initiated. Zero can be passed to
137       disable detection and value '1' indicates that detection should
138       be enabled but limit setting can be omitted.
139
140   regulator-ov-protection-microvolt:
141     description: Set over voltage protection limit. This is a limit where
142       hardware performs emergency shutdown. Zero can be passed to disable
143       protection and value '1' indicates that protection should be enabled but
144       limit setting can be omitted. Limit is given as microvolt offset from
145       voltage set to regulator.
146
147   regulator-ov-error-microvolt:
148     description: Set over voltage error limit. This is a limit where part of
149       the hardware propably is malfunctional and damage prevention is requested
150       Zero can be passed to disable error detection and value '1' indicates
151       that detection should be enabled but limit setting can be omitted. Limit
152       is given as microvolt offset from voltage set to regulator.
153
154   regulator-ov-warn-microvolt:
155     description: Set over voltage warning limit. This is a limit where hardware
156       is assumed still to be functional but approaching limit where it gets
157       damaged. Recovery actions should be initiated. Zero can be passed to
158       disable detection and value '1' indicates that detection should
159       be enabled but limit setting can be omitted. Limit is given as microvolt
160       offset from voltage set to regulator.
161
162   regulator-uv-protection-microvolt:
163     description: Set over under voltage protection limit. This is a limit where
164       hardware performs emergency shutdown. Zero can be passed to disable
165       protection and value '1' indicates that protection should be enabled but
166       limit setting can be omitted. Limit is given as microvolt offset from
167       voltage set to regulator.
168
169   regulator-uv-error-microvolt:
170     description: Set under voltage error limit. This is a limit where part of
171       the hardware propably is malfunctional and damage prevention is requested
172       Zero can be passed to disable error detection and value '1' indicates
173       that detection should be enabled but limit setting can be omitted. Limit
174       is given as microvolt offset from voltage set to regulator.
175
176   regulator-uv-warn-microvolt:
177     description: Set over under voltage warning limit. This is a limit where
178       hardware is assumed still to be functional but approaching limit where
179       it gets damaged. Recovery actions should be initiated. Zero can be passed
180       to disable detection and value '1' indicates that detection should
181       be enabled but limit setting can be omitted. Limit is given as microvolt
182       offset from voltage set to regulator.
183
184   regulator-temp-protection-kelvin:
185     description: Set over temperature protection limit. This is a limit where
186       hardware performs emergency shutdown. Zero can be passed to disable
187       protection and value '1' indicates that protection should be enabled but
188       limit setting can be omitted.
189
190   regulator-temp-error-kelvin:
191     description: Set over temperature error limit. This is a limit where part of
192       the hardware propably is malfunctional and damage prevention is requested
193       Zero can be passed to disable error detection and value '1' indicates
194       that detection should be enabled but limit setting can be omitted.
195
196   regulator-temp-warn-kelvin:
197     description: Set over temperature warning limit. This is a limit where
198       hardware is assumed still to be functional but approaching limit where it
199       gets damaged. Recovery actions should be initiated. Zero can be passed to
200       disable detection and value '1' indicates that detection should
201       be enabled but limit setting can be omitted.
202
203   regulator-active-discharge:
204     description: |
205       tristate, enable/disable active discharge of regulators. The values are:
206       0: Disable active discharge.
207       1: Enable active discharge.
208       Absence of this property will leave configuration to default.
209     $ref: "/schemas/types.yaml#/definitions/uint32"
210     enum: [0, 1]
211
212   regulator-coupled-with:
213     description: Regulators with which the regulator is coupled. The linkage
214       is 2-way - all coupled regulators should be linked with each other.
215       A regulator should not be coupled with its supplier.
216     $ref: "/schemas/types.yaml#/definitions/phandle-array"
217     items:
218       maxItems: 1
219
220   regulator-coupled-max-spread:
221     description: Array of maximum spread between voltages of coupled regulators
222       in microvolts, each value in the array relates to the corresponding
223       couple specified by the regulator-coupled-with property.
224     $ref: "/schemas/types.yaml#/definitions/uint32-array"
225
226   regulator-max-step-microvolt:
227     description: Maximum difference between current and target voltages
228       that can be changed safely in a single step.
229
230 patternProperties:
231   ".*-supply$":
232     description: Input supply phandle(s) for this node
233
234   regulator-state-(standby|mem|disk):
235     type: object
236     description:
237       sub-nodes for regulator state in Standby, Suspend-to-RAM, and
238       Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux
239       sleep states.
240
241     properties:
242       regulator-on-in-suspend:
243         description: regulator should be on in suspend state.
244         type: boolean
245
246       regulator-off-in-suspend:
247         description: regulator should be off in suspend state.
248         type: boolean
249
250       regulator-suspend-min-microvolt:
251         description: minimum voltage may be set in suspend state.
252
253       regulator-suspend-max-microvolt:
254         description: maximum voltage may be set in suspend state.
255
256       regulator-suspend-microvolt:
257         description: the default voltage which regulator would be set in
258           suspend. This property is now deprecated, instead setting voltage
259           for suspend mode via the API which regulator driver provides is
260           recommended.
261
262       regulator-changeable-in-suspend:
263         description: whether the default voltage and the regulator on/off
264           in suspend can be changed in runtime.
265         type: boolean
266
267       regulator-mode:
268         description: operating mode in the given suspend state. The set
269           of possible operating modes depends on the capabilities of every
270           hardware so the valid modes are documented on each regulator device
271           tree binding document.
272         $ref: "/schemas/types.yaml#/definitions/uint32"
273
274     additionalProperties: false
275
276 additionalProperties: true
277
278 examples:
279   - |
280     xyzreg: regulator {
281       regulator-min-microvolt = <1000000>;
282       regulator-max-microvolt = <2500000>;
283       regulator-always-on;
284       vin-supply = <&vin>;
285
286       regulator-state-mem {
287         regulator-on-in-suspend;
288       };
289     };