1 What: /sys/class/leds/<led>/flash_brightness
4 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
5 Description: read/write
6 Set the brightness of this LED in the flash strobe mode, in
7 microamperes. The file is created only for the flash LED devices
8 that support setting flash brightness.
10 The value is between 0 and
11 /sys/class/leds/<led>/max_flash_brightness.
13 What: /sys/class/leds/<led>/max_flash_brightness
16 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
17 Description: read only
18 Maximum brightness level for this LED in the flash strobe mode,
21 What: /sys/class/leds/<led>/flash_timeout
24 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
25 Description: read/write
26 Hardware timeout for flash, in microseconds. The flash strobe
27 is stopped after this period of time has passed from the start
28 of the strobe. The file is created only for the flash LED
29 devices that support setting flash timeout.
31 What: /sys/class/leds/<led>/max_flash_timeout
34 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
35 Description: read only
36 Maximum flash timeout for this LED, in microseconds.
38 What: /sys/class/leds/<led>/flash_strobe
41 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
42 Description: read/write
43 Flash strobe state. When written with 1 it triggers flash strobe
44 and when written with 0 it turns the flash off.
46 On read 1 means that flash is currently strobing and 0 means
49 What: /sys/class/leds/<led>/flash_fault
52 Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
53 Description: read only
54 Space separated list of flash faults that may have occurred.
55 Flash faults are re-read after strobing the flash. Possible
58 * led-over-voltage - flash controller voltage to the flash LED
59 has exceeded the limit specific to the flash controller
60 * flash-timeout-exceeded - the flash strobe was still on when
61 the timeout set by the user has expired; not all flash
62 controllers may set this in all such conditions
63 * controller-over-temperature - the flash controller has
65 * controller-short-circuit - the short circuit protection
66 of the flash controller has been triggered
67 * led-power-supply-over-current - current in the LED power
68 supply has exceeded the limit specific to the flash
70 * indicator-led-fault - the flash controller has detected
71 a short or open circuit condition on the indicator LED
72 * led-under-voltage - flash controller voltage to the flash
73 LED has been below the minimum limit specific to
75 * controller-under-voltage - the input voltage of the flash
76 controller is below the limit under which strobing the
77 flash at full current will not be possible;
78 the condition persists until this flag is no longer set
79 * led-over-temperature - the temperature of the LED has exceeded
80 its allowed upper limit