GNU Linux-libre 5.19-rc6-gnu
[releases.git] / Documentation / ABI / testing / sysfs-bus-iio-sx9324
1 What:           /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup
2 Date:           November 2021
3 KernelVersion:  5.17
4 Contact:        Gwendal Grignou <gwendal@chromium.org>
5 Description:
6                 SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout
7                 defines if the input is
8                 + not connected (HZ),
9                 + grounded (GD),
10                 + connected to an antenna where it can act as a base
11                   (DS - data shield), or measured input (MI).
12
13                 The sensor rotates measurement across 4 phases
14                 (PH0, PH1, PH2, PH3), where the inputs are configured
15                 and then measured.
16
17                 By default,  during the first phase, [PH0], CS0 is measured,
18                 while CS1 and CS2 are used as shields.
19                 `cat in_proximity0_setup` returns "MI,DS,DS".
20                 [PH1], CS1 is measured, CS0 and CS2 are shield:
21                 `cat in_proximity1_setup` returns "DS,MI,DS".
22                 [PH2], CS2 is measured, CS0 and CS1 are shield:
23                 `cat in_proximity1_setup` returns "DS,DS,MI".
24                 [PH3], CS1 and CS2 are measured (combo mode):
25                 `cat in_proximity1_setup` returns "DS,MI,MI".
26
27                 Note, these are the chip default. Hardware layout will most
28                 likely dictate different output. The entry is read-only.