1 What: /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup
4 Contact: Gwendal Grignou <gwendal@chromium.org>
6 SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout
7 defines if the input is
10 + connected to an antenna where it can act as a base
11 (DS - data shield), or measured input (MI).
13 The sensor rotates measurement across 4 phases
14 (PH0, PH1, PH2, PH3), where the inputs are configured
17 By default, during the first phase, [PH0], CS0 is measured,
18 while CS1 and CS2 are used as shields.
19 `cat in_proximity0_setup` returns "MI,DS,DS".
20 [PH1], CS1 is measured, CS0 and CS2 are shield:
21 `cat in_proximity1_setup` returns "DS,MI,DS".
22 [PH2], CS2 is measured, CS0 and CS1 are shield:
23 `cat in_proximity1_setup` returns "DS,DS,MI".
24 [PH3], CS1 and CS2 are measured (combo mode):
25 `cat in_proximity1_setup` returns "DS,MI,MI".
27 Note, these are the chip default. Hardware layout will most