The Inform 6 Programmer's Guide

Chapter 28: The Glulx Architecture

[Glulx] This chapter describes the architecture of the Glulx virtual machine as targeted by the compiler. Glulx is the secondary compilation target, designed to overcome the Z-machine's size and capability limitations by providing a 32-bit address space, unlimited object counts, and a clean separation between the virtual machine and its I/O layer. When invoked with the '- G' switch, the compiler produces Glulx game files (typically with a .ulx extension).

28.1 Design Rationale and Differences from the Z-Machine

The Z-Machine, originally designed by Infocom in the early 1980s, imposes constraints that can limit large or complex works of interactive fiction. Its 16-bit address space caps story files at 512 KB (version 8); it supports at most 65,535 objects (255 in version 3); the dictionary is limited to 6 or 9 characters per word; and its I/O is tightly coupled to the virtual machine itself.

Glulx was created to remove these constraints. Its core design principles are:

  • 32-bit address space. All addresses, values, and object references are 32-bit quantities, providing a practical address space of up to 256 MB.

  • No built-in I/O. All input and output is handled through the Glk library, an external I/O API. This separation keeps the virtual machine simple and allows interpreters to provide rich multimedia capabilities without changing the VM specification.

  • No built-in object structure. Unlike the Z-machine, which defines a fixed object table format in the VM specification, Glulx provides only a flat memory model. The compiler synthesizes its own object table layout in memory (see §28.5).

  • Big-endian byte order. All multi-byte values in memory are stored most-significant byte first.

  • Flat memory model. Memory is a single contiguous array of bytes divided into ROM, RAM, and extended memory segments. There are no packed addresses, no banked memory, and no distinction between "high" and "low" memory.

28.1.1 Selecting Glulx Mode

The compiler targets the Z-machine by default; the -G switch selects Glulx instead (see §12.1.3). In the compiler source, this sets the global variable glulx_mode to TRUE. When Glulx mode is active, the compiler-predefined constant WORDSIZE becomes 4 and the largest positive signed integer is 0x7FFFFFFF, reflecting the 32-bit word size.

28.1.2 Version Numbering and Auto-Selection

Glulx version numbers use a three-part scheme X.Y.Z, encoded as a 32-bit integer: (X << 16) | (Y << 8) | Z. For example, version 3.1.2 is encoded as 0x00030102. The compiler's select_glulx_version() function parses the version string provided by the -v switch in Glulx mode.

If you don't explicitly request a version, the compiler automatically selects the minimum Glulx version required by the features used in the source code. A set of feature flags determines this:

Feature Flag Minimum Version Trigger
uses_unicode_features 3.0.0 streamunichar opcode, or any Unicode character in the text
uses_memheap_features 3.1.0 mzero, mcopy, malloc, mfree opcodes
uses_acceleration_features 3.1.1 accelfunc, accelparam opcodes
uses_float_features 3.1.2 Any single-precision floating-point opcode
uses_extundo_features 3.1.3 hasundo, discardundo opcodes
uses_double_features 3.1.3 Any double-precision floating-point opcode

These flags are set automatically during assembly when the compiler encounters an opcode belonging to a feature-gated group (see assembleg_instruction()). The final output version is the higher of the requested version and the version required by the features used.

28.1.3 Key Differences Summary

Feature Z-Machine Glulx
Word size 16 bits 32 bits
Address space Up to 512 KB (v8) Up to ~256 MB
Packed addresses Yes (scale factors 2, 4, or 8) No - direct byte addresses
Maximum objects 255 (v3) or 65,535 (v4+) No fixed limit
Maximum verbs 255 65,535
Maximum actions 256 (GV1) or 1024 (GV2/3) Effectively unlimited
Maximum attributes 32 (v3) or 48 (v4+) Configurable (up to 312)
Maximum properties 31 (v3) or 63 (v4+) No fixed limit
I/O Built into VM External (Glk API)
Byte order Big-endian Big-endian
Object table Defined by VM spec Compiler-synthesized
Story file extension .z3-.z8 .ulx
Floating point Not supported IEEE-754 single and double

28.2 Memory Layout and GPAGESIZE

Glulx memory is a single contiguous array of bytes, numbered from address zero upward. It is divided into three segments whose boundaries are specified in the file header:

  Address (hex)       Segment
+-----------------+  00000000
|     Header      |
|  (36 bytes)     |
+- - - - - - - - -+  00000024
|                 |
|    ROM          |
|  (read-only)    |
|                 |
+-----------------+  RAMSTART
|                 |
|    RAM          |
|  (read/write)   |
|                 |
+-----------------+  EXTSTART
|                 |
|  Extended       |
|  Memory         |
|  (zeroed on     |
|   load)         |
|                 |
+-----------------+  ENDMEM

28.2.1 Segment Descriptions

ROM (0x00000000 to RAMSTART): The read-only segment contains the 36-byte Glulx header, the Inform-specific static ROM block (24 bytes), the code area, and constant data. The interpreter must not allow the program to write to this region. ROM is always at least 256 bytes long.

RAM (RAMSTART to EXTSTART): The read/write segment contains global variables, object tables, property data, arrays, and other mutable game state. Global variables are stored at the very beginning of RAM, each occupying 4 bytes.

Extended Memory (EXTSTART to ENDMEM): This region is not stored in the game file. The system initializes it to all zeros when the game loads and uses it for heap allocation (malloc/mfree). The MEMORY_MAP_EXTENSION setting determines this region's size.

28.2.2 Page Alignment

All segment boundaries - RAMSTART, EXTSTART, and ENDMEM - must be multiples of GPAGESIZE, which is defined as 256 bytes. The stack size specified in the header must also be a multiple of 256. This alignment requirement simplifies interpreter implementation by ensuring that memory protection boundaries fall on clean page boundaries.

28.3 The 32-Bit Address Space

In the Z-machine, addresses are 16-bit quantities. Routines and strings use "packed addresses" that must be multiplied by a scale factor (2, 4, or 8 depending on the version) to obtain the actual byte address. This packed addressing scheme allows the Z-machine to address more than 64 KB of memory but imposes alignment requirements on code and string placement.

Glulx eliminates packed addresses. All addresses are 32-bit byte addresses. A reference to a routine, string, or data location is simply the byte offset from the start of memory. This has several consequences:

  • No scale factor. The compiler sets scale_factor to 0 in Glulx mode - it is never used.

  • No alignment restrictions on code. Routines can begin at any byte address. Routines don't need to be aligned to even addresses or any particular boundary.

  • Larger story files. Story files can be as large as the 32-bit address space allows (up to 4 GB in theory, though practical limits are much lower).

  • Simpler address arithmetic. All pointer arithmetic operates directly on byte addresses without scaling.

The compiler predefines the constant WORDSIZE as 4 in Glulx mode, reflecting the fact that each machine word occupies 4 bytes. The maximum signed integer value is 0x7FFFFFFF, and the maximum number of local variables per routine is 119 (including sp).

28.4 The Header (36 Bytes)

Every Glulx game file begins with a 36-byte header containing nine 32-bit fields. The header size is defined by GLULX_HEADER_SIZE (36). The compiler writes the header during the output phase.

Offset Size Field Description
0x00 4 Magic number The ASCII string Glul (bytes 47 6C 75 6C).
0x04 4 Version Glulx version in (major << 16) \| (minor << 8) \| patch format.
0x08 4 RAMSTART Byte address of the first writable memory location.
0x0C 4 EXTSTART Byte address where extended memory begins; equals the game file size.
0x10 4 ENDMEM Total memory size needed at runtime (EXTSTART + MEMORY_MAP_EXTENSION).
0x14 4 Stack size Maximum stack size in bytes (must be a multiple of 256).
0x18 4 Start function Address of the first function to call at startup.
0x1C 4 Decoding table Address of the string-decoding (Huffman) table, or 0 if none.
0x20 4 Checksum 32-bit checksum of the entire file, computed with this field set to 0.

The start function field points to the beginning of the code area (Write_Code_At), and the decoding table points to the string compression table (Write_Strings_At). Both are set during the output phase.

The checksum is computed as the sum of all bytes in the initial memory image (ROM + RAM), treating each group of 4 bytes as a big-endian 32-bit integer. The checksum field itself is set to zero during computation and filled in afterward.

28.4.1 The Inform Static ROM Block

Immediately after the 36-byte Glulx header, the compiler writes a 24-byte Inform-specific block (GLULX_STATIC_ROM_SIZE). This block is part of ROM and is written immediately after the header:

Offset Size Content
0x24 4 The ASCII string Info (Inform identifier).
0x28 4 Memory-layout identifier continuation: the four bytes 00 01 00 00.
0x2C 4 Inform compiler version as four ASCII characters in the form M.NN (e.g., 6.44).
0x30 4 Glulx back-end (code-generator) version, encoding GLULX_RELEASE_NUMBER in the same M.NN ASCII layout (in 6.44 this is 0.38).
0x34 2 Game release number.
0x36 6 Game serial number (6 ASCII characters, typically a date YYMMDD).

Together with the 36-byte Glulx header, the leading eight bytes of the static ROM block (Info followed by 00 01 00 00) form a conventional memory-layout identifier that interpreters can use to recognize an Inform-compiled Glulx file.

28.4.2 Version Compatibility

An interpreter with version X.Y.Z can run game files with version numbers from X.0.0 up to X.Y.* (any patch level). As a special case, version 3.x interpreters also accept game files compiled for version 2.0.0, ensuring backward compatibility with games compiled before the Unicode extensions were introduced.

28.5 Object Table Layout

Unlike the Z-Machine, which defines a fixed object table format in the VM specification, Glulx provides no built-in object structure. The compiler synthesizes its own object table in the RAM segment. Understanding this layout is important for advanced debugging and for writing assembly code that manipulates objects directly.

28.5.1 The Object Record

The objecttg structure represents each Glulx object. In the compiled output, each object occupies a contiguous block of memory with the following byte layout:

Byte offset Size Field Description
0 1 byte Type byte Always 0x70 (the metaclass tag for "object").
1 NUM_ATTR_BYTES bytes Attributes Bit array of attributes.
1 + NUM_ATTR_BYTES 4 bytes Chain (next) Address of the next object in the linked list, or 0 at the end.
5 + NUM_ATTR_BYTES 4 bytes Short name Address of the object's short name string.
9 + NUM_ATTR_BYTES 4 bytes Property table Address of the object's property table.
13 + NUM_ATTR_BYTES 4 bytes Parent Address of the parent object record, or 0.
17 + NUM_ATTR_BYTES 4 bytes Sibling Address of the next sibling object record, or 0.
21 + NUM_ATTR_BYTES 4 bytes Child Address of the first child object record, or 0.
25 + NUM_ATTR_BYTES GLULX_OBJECT_EXT_BYTES Extension Reserved padding (zero by default).

The interpreter accesses the chain, name, property-table, and tree-pointer fields by word offset rather than byte offset. The word offsets are defined by the GOBJFIELD_* macros (the compiler forces NUM_ATTR_BYTES to be congruent to 3 modulo 4 so that these fields fall on 4-byte boundaries):

#define GOBJFIELD_CHAIN()    (1+((NUM_ATTR_BYTES)/4))
#define GOBJFIELD_NAME()     (2+((NUM_ATTR_BYTES)/4))
#define GOBJFIELD_PROPTAB()  (3+((NUM_ATTR_BYTES)/4))
#define GOBJFIELD_PARENT()   (4+((NUM_ATTR_BYTES)/4))
#define GOBJFIELD_SIBLING()  (5+((NUM_ATTR_BYTES)/4))
#define GOBJFIELD_CHILD()    (6+((NUM_ATTR_BYTES)/4))

The total size of each object in bytes is OBJECT_BYTE_LENGTH, computed as 1 + NUM_ATTR_BYTES + 6*4 + GLULX_OBJECT_EXT_BYTES.

28.5.2 Attributes

Attributes in Glulx are stored as a byte array at the start of each object record, rather than as a fixed-size bit field. The NUM_ATTR_BYTES compiler setting controls the number of attribute bytes, with a maximum of 39 (MAX_NUM_ATTR_BYTES). Each byte holds 8 attribute flags, so the maximum number of attributes is 312 (39 × 8). By contrast, the Z-machine supports at most 48 attributes (6 bytes in versions 4+).

The default value of NUM_ATTR_BYTES is 7 (providing 56 attributes), which is sufficient for the standard library. Games that need more attributes can increase this setting via the compiler's $ dollar options.

28.5.3 Properties

Each object has a property table whose address the object record stores. The property table contains a sequence of property entries, each described by the propg structure:

typedef struct propg {
    int num;           /* Property number */
    int continuation;  /* Continuation flag */
    int flags;         /* Property flags */
    int32 datastart;   /* Offset into property data area */
    int32 datalen;     /* Length of property data in bytes */
} propg;

Unlike the Z-machine, where property numbers are limited to 31 (v3) or 63 (v4+), Glulx property numbers have no fixed upper limit. The compiler's individual property numbering begins at INDIV_PROP_START (typically 256 in Glulx mode).

28.5.4 Comparison with Z-Machine Objects

Feature Z-Machine (v4+) Glulx
Maximum objects 65,535 No fixed limit
Attribute bytes 6 (48 attributes) Configurable, up to 39 (312 attributes)
Tree pointers 16-bit (parent, sibling, child) 32-bit
Property numbers 1-63 No fixed limit
Property table Fixed format, in-line data Flexible, separate data area
Object record size 14 bytes (fixed) Variable (depends on NUM_ATTR_BYTES)

28.6 Stack Architecture

The interpreter maintains the Glulx stack separately from main memory. It is not addressable in the memory map; the program cannot read or write arbitrary stack locations using memory access opcodes.

28.6.1 Stack Basics

The stack pointer starts at zero and grows upward, measured in bytes. The header (offset 0x14) specifies the maximum stack size, which must be a multiple of 256. All values pushed onto the stack are naturally aligned: 32-bit values are placed at addresses that are multiples of 4, and 16-bit values at even addresses.

28.6.2 Call Frames

When a function is called, a new call frame is pushed onto the stack. The call frame has the following structure:

FramePtr + 0:             Frame Length (4 bytes)
FramePtr + 4:             Locals Position (4 bytes)
FramePtr + 8:             Format of Locals
                            LocalType/LocalCount pairs (2 bytes each)
                            Terminated by 0/0
                            Padded to reach 4-byte alignment
FramePtr + LocalsPos:     Local variables
                            (1, 2, or 4 bytes each, naturally aligned)
FramePtr + FrameLen:      Base of pushed values (grows upward)

The Frame Length records the total size of the frame header and local variables. Above this point, the function can push and pop temporary 32-bit values for intermediate computations. A function cannot pop values below its own FramePtr + FrameLen boundary.

28.6.3 Call Stubs

When a function call, catch, or string-printing operation needs to save a return context, a call stub is pushed onto the stack before the new call frame:

DestType   (4 bytes)   - how to store the return value
DestAddr   (4 bytes)   - where to store it
PC         (4 bytes)   - return address
FramePtr   (4 bytes)   - caller's frame pointer

The DestType field indicates what to do with the value returned by the called function:

DestType Meaning
0 Discard the return value.
1 Store in main memory at DestAddr.
2 Store in a local variable at frame offset DestAddr.
3 Push onto the stack.
10 Resume printing a compressed (E1 Huffman) string.
11 Resume function execution after embedded string printing.
12 Resume printing a decimal integer.
13 Resume printing a C-style (E0) string.
14 Resume printing a Unicode (E2) string.

DestType values 10-14 are used internally by the interpreter during string-printing operations and are not generated directly by compiled code.

28.6.4 Stack Manipulation Opcodes

Five opcodes provide direct stack manipulation:

Opcode Code Description
stkcount 0x50 Returns the number of values above the current frame.
stkpeek 0x51 Reads the Nth value from the top (0 = topmost).
stkswap 0x52 Swaps the top two values.
stkroll 0x53 Rotates the top N values by M positions.
stkcopy 0x54 Duplicates the top N values.

These opcodes operate only on values above FramePtr + FrameLen; they cannot access local variables or the frame header. See §29 for the complete opcode reference.

28.7 Glulx Instruction Set Overview

Glulx instructions use a variable-length encoding with three parts: the opcode number, operand addressing mode bytes, and operand data. This section provides an overview; §29 documents every opcode in detail.

28.7.1 Instruction Format

[Opcode: 1-4 bytes] [Mode bytes: ⌈N/2⌉ bytes] [Operand data: 0-4 bytes each]

The opcode number is encoded using 1, 2, or 4 bytes, detected by the top two bits of the first byte:

First Byte Pattern Opcode Size Range
0xxxxxxx 1 byte 0x00-0x7F
10xxxxxx 2 bytes 0x0000-0x3FFF
11xxxxxx 4 bytes 0x00000000-0x3FFFFFFF

The mode bytes encode the addressing mode for each operand, with two operand modes packed per byte (lower nibble first). If an instruction has an odd number of operands, the upper nibble of the last mode byte is unused.

Each operand then follows, consuming 0 to 4 bytes depending on its addressing mode.

28.7.2 Opcode Categories

The compiler's opcode table defines over 130 opcodes organized into the following categories:

Category Opcode Range Count Description
Integer arithmetic 0x10-0x1E 13 Addition, subtraction, bitwise ops, shifts
Branching 0x20-0x2D, 0x104 14 Conditional and unconditional jumps
Function calls 0x30-0x34, 0x160-0x163 9 Call, return, catch/throw, tail call
Data movement 0x40-0x45 5 Copy, sign-extend
Array access 0x48-0x4F 8 Load/store at computed addresses
Stack operations 0x50-0x54 5 Count, peek, swap, roll, copy
Output 0x70-0x73 4 Stream character, number, string, Unicode char
Miscellaneous 0x00, 0x0100-0x0103, 0x0110-0x0111 7 nop, gestalt, memory size, random, debug
Game state 0x0120-0x0129 10 Save, restore, undo, quit, verify, protect
Glk interface 0x0130 1 Call Glk API function
String tables 0x0140-0x0141 2 Get/set string decoding table
I/O system 0x0148-0x0149 2 Get/set I/O system
Search 0x0150-0x0152 3 Linear, binary, and linked list search
Memory/heap 0x170-0x179 4 Zero, copy, malloc, free
Acceleration 0x180-0x181 2 Register accelerated functions
Floating point 0x190-0x1C9 29 Single-precision IEEE-754 operations
Double precision 0x200-0x239 32 Double-precision IEEE-754 operations

28.7.3 Feature-Gated Opcode Groups

Several opcode groups are gated behind feature flags. When the compiler encounters an opcode from one of these groups, it automatically sets the corresponding feature flag and adjusts the minimum Glulx version requirement. The flags are defined as bit constants:

Flag Constant Value Feature Minimum Version
GOP_Unicode 1 Unicode output 3.0.0
GOP_MemHeap 2 Memory and heap operations 3.1.0
GOP_Acceleration 4 Function acceleration 3.1.1
GOP_Float 8 Single-precision floating point 3.1.2
GOP_ExtUndo 16 Extended undo (has/discard) 3.1.3
GOP_Double 32 Double-precision floating point 3.1.3

28.8 The Glk I/O Layer

Glulx includes no built-in I/O facilities. Instead, the Glk library handles all input and output, an external API designed for portable interactive fiction I/O. This differs fundamentally from the Z-Machine, which includes dozens of I/O-related opcodes for text display, cursor control, sound, and graphics.

28.8.1 I/O System Modes

The Glulx VM supports multiple I/O system modes, selected at runtime via the setiosys opcode. The available modes are:

Mode Value Description
Null 0 All output is silently discarded.
Filter 1 Each output character is passed to a program-specified function.
Glk 2 Output uses the Glk API (the standard mode).
FyreVM 0x20 An alternative I/O system used by the FyreVM interpreter.

When the VM starts, the null I/O system is active. The program must explicitly select the Glk system (typically with @setiosys 2 0;) before any output appears. The standard library performs this switch during initialization.

28.8.2 The @glk Opcode

The @glk opcode (0x0130) is the primary interface between Glulx programs and the Glk library. It takes three operands:

@glk selector argcount result;
  • selector: The Glk function identifier (e.g., $0080 for glk_put_char).
  • argcount: The number of arguments, which have been pushed onto the stack before the opcode executes.
  • result: The destination for the Glk function's return value.

Arguments must be pushed onto the stack in reverse order (last argument pushed first) so that the first argument is on top of the stack when the opcode executes.

The Glk function selectors are defined in the external header file infglk.h, which is not part of the compiler itself but is distributed with the standard library toolkit. Programs include this file to obtain named constants for all Glk functions.

28.8.3 The Glk__Wrap Veneer Routine

The compiler generates a veneer routine called Glk__Wrap that provides a high-level calling interface for Glk functions. When source code calls glk() as a system function, the compiler emits a call to Glk__Wrap.

The Glk__Wrap routine is a _vararg_count function that:

  1. Pops the Glk function selector from the stack.
  2. Decrements the argument count (since the selector is not a Glk argument).
  3. Calls @glk with the selector, remaining argument count, and a result variable.
  4. Returns the result.
! The Glk__Wrap veneer routine (simplified):
[ Glk__Wrap _vararg_count callid retval;
    @copy sp callid;
    _vararg_count = _vararg_count - 1;
    @glk callid _vararg_count retval;
    return retval;
];

28.8.4 Output Opcodes

Four opcodes produce output through the current I/O system:

Opcode Code Description
streamchar 0x70 Output a single 8-bit character.
streamnum 0x71 Output a signed decimal integer.
streamstr 0x72 Output a string object (decoded from memory).
streamunichar 0x73 Output a single 32-bit Unicode character.

The streamstr opcode handles three string formats, identified by the first byte of the string object:

  • E0: A C-style null-terminated string of 8-bit characters.
  • E1: A Huffman-compressed string (decoded using the table at header offset 0x1C).
  • E2: A null-terminated string of 32-bit Unicode characters (with 3 bytes of padding after the type byte).

28.8.5 String Decoding Table

Compressed (E1) strings are decoded using a Huffman tree whose structure is stored in memory at the address given in the header (offset 0x1C). The decoding table format is:

Offset Size Field
0x00 4 Table length in bytes.
0x04 4 Number of nodes.
0x08 4 Address of the root node.
0x0C+ variable Node data.

Each node is identified by its first byte:

Type Structure Meaning
0x00 Left pointer (4) + right pointer (4) Branch node.
0x01 (none) String terminator.
0x02 Character (1 byte) Single Latin-1 character.
0x03 Characters + null terminator C-style string.
0x04 Character (4 bytes) Single Unicode character.
0x05 Characters (4 bytes each) + null (4 bytes) Unicode string.
0x08 Address (4 bytes) Indirect reference to string or function.
0x09 Address (4 bytes) Double indirect (address points to pointer).

Decoding reads one bit at a time from the compressed data. A 0 bit follows the left branch; a 1 bit follows the right branch. When decoding reaches a leaf node, it performs its action (print character, call function, etc.) and resumes from the root.

28.8.6 Gestalt Queries

A program can test whether the interpreter supports a particular I/O system using the gestalt opcode with selector 4 (IOSystem):

! Check if Glk I/O is supported:
@gestalt 4 2 result;  ! selector=IOSystem, value=Glk
if (result) {
    @setiosys 2 0;    ! Enable Glk I/O
}

28.9 Floating-Point Support

Glulx provides native support for IEEE-754 floating-point arithmetic, a feature the Z-machine lacks. Floating-point values are stored in the same 32-bit word format as integers - the interpretation depends on which opcodes are used to manipulate them.

28.9.1 Single-Precision Format (IEEE-754)

Single-precision floats use the standard IEEE-754 32-bit format, stored in big-endian byte order:

Bit 31:        Sign (S) - 0 = positive, 1 = negative
Bits 30-23:    Exponent (E) - 8 bits, biased by 127
Bits 22-0:     Mantissa (M) - 23 bits (implicit leading 1)

Some useful reference values:

Value Hex Encoding
0.0 $00000000
1.0 $3F800000
-1.0 $BF800000
2.0 $40000000
0.5 $3F000000
+Infinity $7F800000
-Infinity $FF800000
NaN (typical) $7FC00000

28.9.2 Float Literals in Source Code

The compiler supports floating-point literals when compiling for Glulx. The lexer's construct_float() function converts a decimal floating-point number into its IEEE-754 binary representation. Float literals use the syntax:

! Float literal examples (Glulx only):
Global pi = $+3.14159;
Global neg = $-1.0;
Global sci = $+6.022e23;

The $+ or $- prefix distinguishes float literals from integer hex constants. Using float literals when compiling for the Z-machine produces an error.

28.9.3 Single-Precision Opcodes

Twenty-nine single-precision floating-point opcodes - conversions, rounding, the four basic arithmetic operations plus fmod, the transcendental functions, comparison branches, and NaN/infinity tests - are gated behind the GOP_Float feature flag and require Glulx version 3.1.2 or later. They are cataloged with their operands in §29.3.14.

NaN values are "sticky" - nearly any arithmetic operation involving NaN produces NaN, and the comparison opcodes treat NaN as not equal to anything, including itself.

28.9.4 Double-Precision Support

Glulx 3.1.3 adds 64-bit double-precision floating-point values. Since Glulx is a 32-bit machine, each double is represented as a pair of 32-bit words: the high word holds the sign bit, the 11-bit exponent, and the upper 20 bits of the mantissa; the low word holds the remaining 32 bits. Thirty-two double-precision opcodes mirror the single-precision set; they are gated behind the GOP_Double feature flag, require Glulx version 3.1.3 or later, and are cataloged in §29.3.15. Because each double occupies two words, many take more operands than their single-precision counterparts (e.g., dadd takes 6 operands: two pairs of inputs and one pair of outputs).

28.10 Acceleration and Performance

Glulx interpreters typically execute bytecode by interpreting each instruction one at a time. For performance-critical routines that are called very frequently - particularly the veneer routines that implement the object system - this interpretation overhead can become significant. The acceleration mechanism allows an interpreter to replace specific bytecode functions with native implementations.

28.10.1 The Acceleration Opcodes

Two opcodes control acceleration, gated behind the GOP_Acceleration feature flag requiring Glulx version 3.1.1:

Opcode Code Operands Description
accelfunc 0x180 L1, L2 Request that function number L1 be provided at address L2.
accelparam 0x181 L1, L2 Set acceleration parameter L1 to value L2.

The accelfunc opcode tells the interpreter: "The function at address L2 corresponds to standard function number L1. If you have a native implementation of function L1, use it instead of interpreting the bytecode at L2."

28.10.2 Acceleration Parameters

Before registering accelerated functions, the program must provide several parameters that the native implementations need:

Parameter Index Description
classes_table 0 Address of the class table.
indiv_prop_start 1 First individual property number.
class_metaclass 2 Address of the Class metaclass object.
object_metaclass 3 Address of the Object metaclass object.
routine_metaclass 4 Address of the Routine metaclass object.
string_metaclass 5 Address of the String metaclass object.
self 6 Address of the self global variable.
num_attr_bytes 7 Number of attribute bytes per object.
cpv_start 8 Start of common property values.

28.10.3 Standard Accelerated Functions

The following function numbers are defined as standard accelerated functions:

Number Function Purpose
1 Z__Region Determine the type region of a value.
8 CP__Tab Property table lookup.
9 RA__Pr Read array property.
10 RL__Pr Read property length.
11 OC__Cl Object-class membership test.
12 RV__Pr Read property value.
13 OP__Pr Test whether an object provides a property.

Functions 2-7 are deprecated and should not be used when NUM_ATTR_BYTES differs from the default value, as they assume a fixed attribute size.

28.10.4 Restrictions and Behavior

Accelerated functions have several restrictions:

  • They cannot make VM function calls - all logic must be implemented natively within the interpreter.
  • They cannot use streaming output (streamchar, streamnum, streamstr).
  • Errors are fatal - unlike their bytecode equivalents, which may call RT__Err, accelerated functions cannot recover from errors.
  • Acceleration state is not saved as part of the game state. After a restore operation, the program must re-register all accelerated functions.

A program should query the interpreter's capabilities before attempting to use acceleration:

! Check if acceleration is supported:
@gestalt 9 0 result;    ! Acceleration gestalt selector
if (result) {
    ! Check if specific function 1 (Z__Region) is available:
    @gestalt 10 1 result;  ! AccelFunc gestalt selector
    if (result) {
        @accelparam 0 classes_table;
        @accelparam 1 INDIV_PROP_START;
        ! ... set remaining parameters ...
        @accelfunc 1 Z__Region;
    }
}